AccuraSEE MINI Gebruikershandleiding - Pagina 3
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} AccuraSEE MINI. AccuraSEE MINI 5 pagina's. Portable heat recovery ventilator
Installation
Please, adhere to the following instructions when installing the product:
NOTE
The product shall not be
The product shall not be installed near hazardous or toxic materials.
installed at a location
where there is probable
The product shall only be installed in either vertical or horizontal
contact with liquids.
orientations and shall not be positioned at an oblique angle.
NOTE
The product shall be
The product shall be installed in horizontal orientation as shown in
carefully positioned
Figure 2(a).
such that it may not trip
and cause property
The product shall be installed in vertical orientation as depicted in
damage or bodily injury.
Figure 2(b).
NOTE
The product shall not be
The product can be sited on a table / floor or mounted on a wall.
installed at a location
where there is excessive
The product shall be installed in a space where the temperature and
heat or exposure to
relative humidity of air are within the range of 22ºC – 26ºC
direct sunlight.
(71.6ºF – 78.8ºF) and 35% – 50%, respectively.
NOTE
The pre-installed supply and exhaust ducts shall be insulated.
Accessories such as
screens, boards, duct
insulation, AC-to-DC
The vents and ducts shall NOT be connected to external appliances
power adapters, self-
such as dryers, fans, furnaces, etc.
tapping screws, and
wall-mounting brackets
are third-party goods
The product shall not be powered until the ducts are installed.
which may not be
provided by the
Window/Door: A pair of boards with each having one hole or a single
manufacturer.
board with two holes shall be fastened to a section of a window/door, and
NOTE
the ducts shall be inserted into the holes.
The product may be
mounted on a wall by
Wall: The ducts shall be inserted into two holes that are drilled through
using four wall-
the wall.
mounting brackets and
four M5 × 10mm self-
tapping screws.
To power the product, connect the plug of the power adapter to the wall
power. Next, connect the free end of the power adapter to the power
NOTE
connector port and the product will operate in the Normal mode. The
The board(s)/wall holes
Boost mode can be activated by pressing the power switch until it latches.
shall be ≥3 in (~7.6 cm).
To shut down the product, ensure that the Normal mode is active. Next,
NOTE
disconnect the power adapter cord from the power connector port, and
The Boost mode can be
disconnect the plug of the power adapter from the wall power.
transitioned to Normal
by simply unlatching the
power switch.
3
Figure 2. Schematic depiction of the installation of the product in (a) horizontal (side view) and
(b) vertical (front view) orientations.
Although the supply duct is not visible in Figure 2(a), it may be connected to the board(s) to interface with the outdoors.
Note. Figure 2 is not drawn to scale.
NOTE
RECOMMENDATIONS
Please comply with all
Screens, which are not provided by the manufacturer, may be attached to the holes of the
applicable codes and
board(s), ducts, or wall to prevent encroaching organisms from damaging the product or
regulations when
constituting hazard to the space where the product is installed.
installing the product.
When installing the product, a minimum separation distance of 1 ft is recommended
between the supply and exhaust ducts.
The ducts should be installed without any bends that may impede the flow of air.
(a) Horizontal orientation.
(b) Vertical orientation.
4