Creda Non pumped Installatie- en gebruikershandleiding - Pagina 9
Blader online of download pdf Installatie- en gebruikershandleiding voor {categorie_naam} Creda Non pumped. Creda Non pumped 10 pagina's. Thermostatic digital mixer shower electronic remote control mixer shower

User Instructions
Warning
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Important
•
Ensure that there is no standing water in the shower tray or bath when the remote control is in use.
(The remote control is protected against water spray but IS NOT protected against immersion).
a) Switching the shower on and off
• The shower is switched on and off by pressing the Start / Stop button
- Pressing the start button will switch the shower on. The selected temperature is
shown in the display when the button is first pressed.
- The temperature display will flash and gradually climb up to the selected
temperature.
(When the temperature is reached, the digit will stop flashing and the handset will bleep
twice, with the backlight coming on for 2 seconds).
- The display will also show the flow rate level.
• The shower can also be switched on using one of the preset programmable buttons
(2 or 3 buttons depending on model).
Two program button remote
- Press one of the Program buttons to switch the shower on at a previously saved temperature
and flow rate. (To save settings : See section on Program buttons).
Notes: If there are no settings in a Programmable button, then the shower will sound a long bleep
and not switch on using that button.
If a program button conflicts with the requirements of the DIP switches then the button will
be ignored and the handset will sound a long "error" bleep.
(See section "Adjusting the remote control" on Page 11, for information about the DIP
switches).
b) Adjusting the temperature and flow
•
Press the Temperature buttons to adjust the temperature.
The temperature adjustment is from
L (low), then 1 to 9, then H (high)
Display
L
1
2
Approx
à à Range increases from approx 34°C to approx 44°C à à
Temperature
25°C
Note : Temperature adjustment range may be limited to 1 - 5
(See section "Restrict range of adjustment of Temperature buttons" on Page 11)
Temporary over-ride : Press Warmer and Cooler buttons together for more than 2 seconds.
Three program button remote
Temp
Decrease
Increase
3
4
5
6
7
8
9
_12_
•
Insert the 2 x AAA batteries (supplied) into the remote control battery compartment
e)
Commissioning the system
Make sure cold and hot water supplies are both turned on and primed.
(To prime, it may be necessary to temporarily partially loosen the cold and hot connections, in turn)
Make sure remote control handset has its batteries installed
Switch on the power supply to the base unit. (In the first 10 seconds of powering up, the base unit
carries out a self check routine. During this time the internal electrical components will momentarily
switch on and off).
Bleed the air out of the base unit
• Before the unit can function correctly the air must be bled from the base unit and associated pipes
Temp
• To bleed the air from the Pumped base unit :
- Make sure the cold and hot delivery pipes are primed prior to connection. (See above)
- Make sure the power to the base unit has been on for LESS than 5 minutes.
Remotes with 2 program buttons
Press P1 and P2
together for at least 3
H
seconds.
Approx
46°C
- "C" will appear on the remote control and the shower will automatically bleed out any air.
Schematic of Non Pumped base
unit (Non Pumped Model)
1. Cold inlet valve
2. Hot inlet valve
4. Stepper motor for
temperature adjustment
5. Potentiometer position
sensor
6. Mixing chamber and valve
7. Flow adjustment
8. Stepper motor / Sensor
9. Control PCB
10. Outlet temperature sensor
Remove battery cover and insert
2 x AAA batteries.
(Observe polarity).
Remotes with 3 program buttons
Press P1 and P3
together for at least 3
seconds.
_9_