www.aal.net
MicroCore Upgrade Kit Installation Guide
TM
Fixture: Universe Collection Medium (UCM) (HID to LED)
1.
REMOVE EXISTING REFLECTOR ASSEMBLY
TURN OFF ALL POWER TO
!
THE UNIT AND TAKE
PROPER SAFETY PRECAUTIONS.
FAILURE TO DO SO MAY RESULT
IN SERIOUS PERSONAL INJURY.
1. Open lower lens frame of the housing by
undoing (2) captive thumb screws located on
underside of fixture and swinging door frame
open as shown in Fig. 1-1 & Fig. 1-1A.
2. Allow door frame assembly to hang freely
as shown in Fig. 1-2
3. Remove existing reflector assembly by
prying housing from fixture. Existing reflector
assembly is held via ball socket studs as
shown in Fig. 1-3.
4. Disconnect reflector assembly and set
aside as shown in Fig. 1-4
DOOR FRAME
ASSEMBLY
93046644 REV. D
Tel(626)968-5666
Fax(626)968-5716
FIG. 1-1