QUICK GUIDE INSTRUCTIONS
Installation
Install the 24V Robo sliding gate motor as per the enclosed instructions.
Important! For safety reasons, a sturdy rail-stop must be securely fitted to the track of the sliding gate in the
fully open position, and in the closed position if there is no other physical stop.
The installation of Safety Beams is strongly recommended, especially if Auto-close is to be used. If Auto-
close is selected and Safety Beams are not fitted, the gate will not operate, unless a wire link is fitted from
'0V-COM' to 'Beam N.C.'. This is, however, not advised.
The 24V Robo is designed to operate on 220V mains supply and a built-in 24V battery. A
Wiring
suitable mains supply must be provided to the site of the gate motor.
L N N L
+ - + -
LAMP
BATTERY MOTOR
MAINS
230V~
Initial Power-up
1.
Put the machine in 'Manual' by unlocking and pulling the Manual Over-ride Lever, and position the
gate mid-way.
2.
Connect the two batteries with the white jumper lead provided, and switch on the mains.
3.
Engage the Manual Over-ride Lever. The display will flash 'S C' and the motor will start running slowly.
4.
Check that the gate is closing, in which case skip to 6. If not, go to step 5.
5.
Pull the Manual Over-ride Lever. Referring to Fig. 1, swap the Motor wires on the second plug. Re-
engage the Manual Over-ride Lever and the motor will close slowly.
6.
On reaching the closed position, the operator will detect the rail-stop and halt, and display "C".
Once the operator has found the closed position, it is then necessary to learn the open position, as
described in the next section. Important! For safety reasons, a sturdy rail-stop must be securely fitted to
the track of the sliding gate in the fully open position.
SLIDING GATE OPERATOR
PROGRAM DISPLAY
PLUGGABLE MEMORY
ENTER BUTTON
SELECT BUTTON
STANDARD
PARTIAL
CONTROL
LOCK
ON/
LIGHT
OFF
0V-COM
BEAM N.C.
BEAM 24V+ BEAM 24V+
GATE
STATUS LED+
ANTENNA
0V-COM
MANUAL
ENCODER
Fig. 1
24V DC
Refer to Fig. 1
With the mains supply isolated, connect
Earth, Line and Neutral.
An external lamp may be optionally
connected to the terminals marked N
and L, LAMP, 230V~. This lamp will
come on with every gate operation
TYPE
COMMERCIAL
and time-out after three minutes
PARTIAL
OPEN
Accessories
STOP
Connect the accessories as indicated,
CLOSE
referenced to '0V-COM'.
0V-COM
All inputs, excepting the Beam, are
BEAM N.C.
'Normally Open'.
GATE
STATUS LED+
If an off-board Receiver is to be used,
connect it to 'BATTERY + and -, and the
N.O. output to 'CONTROL/OPEN'.
The common of the receiver must be
linked to negative.
Note 1: Do not use 12v devices by
connecting them to one of the
batteries, as this will cause improper
charging.
Note 2: The 24 volt supply from the
Robo24 controller ('BATTERY +, -') is
suitable for powering one or two safety
beams and an extra receiver. Traffic
Detector Loops, Intercoms, CCTV
Cameras etc., must use their own
power supplies.