Archon WD2010H Handleiding voor installatie, bediening en onderhoud - Pagina 3
Blader online of download pdf Handleiding voor installatie, bediening en onderhoud voor {categorie_naam} Archon WD2010H. Archon WD2010H 16 pagina's. Washdown stations
INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR
ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS
C. Application Data: Recommended Operating Ranges
Model
Saturated Steam Pressure
WD2010L
WD2010
WD2010 H
Maximum water discharge temperature should be limited to 190° F.
Note: For specific application data within the above ranges, consult the Archon product proposal or request Archon
to supply the applicable Technical Data Bulletin.
DANGER: Never exceed these design ratings or application data limits.
Exceeding these limits can cause serious personal injury and/or property
damage. The hot water coming out of the unit may flash to steam if the
outlet temperature reading is more than 190° F. The washdown units should
never be used for temperatures exceeding 190°F.
DANGER: Archon WD2010 washdown stations are designed as systems.
Operation without hose and approved nozzle to provide back pressure can
result in personal injury to personnel and damage to property. Consult the
factory for optional installation instructions.
II.
INSPECTION AND PERFORMANCE CONFIRMATION:
A. Receiving Inspection
Upon receipt of washdown station, check all components carefully for damage incurred in shipping. If damage is
evident or suspected, do not attempt installation. Notify carrier immediately and request damage inspection.
(psig)
10-60
35-150
60-200
DANGER
DANGER
Water Pressure
(psig)
30-80
30-80
30-80
3
Discharge flow range
3.0 to 4.5 GPM
5.5 to 8.5 GPM
6.5 to 9.0 GPM
Installation: 1004 Rev 4
Issued: February 7, 2013