Sharp AR-M208 Servicehandleiding - Pagina 16

Blader online of download pdf Servicehandleiding voor {categorie_naam} Sharp AR-M208. Sharp AR-M208 32 pagina's. Digital laser copier/ printer
Ook voor Sharp AR-M208: Gebruikershandleiding (24 pagina's)

(Initial screen)
(Executing screen)
Sim3-3 OUTPUT CHECK
Sim3-3 OUTPUT CHECK
1:JGM1
4:FM-1200
7:STM
2:JGM2
5:EVM
8:OGSLR
3:FM-600 6:OFM
9:OGSLL
1/3
EXEC
2/3
During execution, [EXEC] is highlighted. Under this state, press the
[BACK] key to interrupt the operation.
Side guide plate drive motor
1:JGM1
Rear edge plate drive motor
2:JGM2
Finisher main motor (600dpi)
3:FM-600
Finisher main motot (1200dpi)
4:FM-1200
Tray lift-up motor
5:EVM
Tray offset motor
6:OFM
Staple operation motor
7:STM
Transport selection gate solenoid (R)
8:OGSLR
Transport selection gate solenoid (L)
9:OGSLL
Rear edge plate drive solenoid
10:JGSL1
Upper alignment plate drive solenoid
11:JGSL2
Shutter drive solenoid
12:SHTSL
Paper exit roller clutch
13:T2SCL
Paper holding solenoid
14:STGSL
The finisher main motor operates for 10sec, the staple motor 5 times,
the tray lift-up motor one reciprocating operation, other motors max. 20
reciprocating operations from the home position, the solenoid repeats
500msec ON and 500msec OFF 20 times.
The staple operation motor operates only when there is no cartridge
installed.
Note:Executable only when the finisher is installed.
8
8-1
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the
(Purpose)
developing bias voltage in each copy mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-1 DV BIAS COPY
Sim8-1 DV BIAS COPY
1:AE
400
5:SUPER PHOTO
2:TEXT
450
3:TEXT/PHOTO
450
1/2
EXEC [200-550]
Display items
Content
AE ( )
1:AE
Character
2:TEXT
Character/Photo
3:TEXT/PHOTO
Photo
4:PHOTO
Super photo
5:SUPER PHOTO *
Toner save
6:TONER SAVE
( ) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
10:JGSL1
11:JGSL2
12:SHTSL
EXEC
8
Disabled
Sim8-1 DV BIAS COPY
400
5:SUPER PHOTO
400
400
EXEC
[200-550]
400
Installation
Default
range
200-550
400 (–400V)
450 (–450V)
450 (–450V)
450 (–450V)
Disabled
376 (–376V)
AR-M208 SIMULATION 8 - 2
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.
8-2
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the main
(Purpose)
charger grid voltage (high mode) in each copy mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-2 MHV(H) COPY
Sim8-2 MHV(H) COPY
5:SUPER PHOTO
1:AE
3
2:TEXT
5
3:TEXT/PHOTO
5
1/2
EXEC [ 1- 8]
Display items
Content
AE ( )
1:AE
Character
2:TEXT
Character/Photo
3:TEXT/PHOTO
Photo
4:PHOTO
Super photo
5:SUPER PHOTO *
Toner save
6:TONER SAVE
( ) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
NO.
Set value
Grid High
1
480
–480V
2
505
–505V
3
530
–530V
4
555
–555V
5
580
–580V
6
605
–605V
7
630
–630V
8
655
–655V
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
8-3
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the main
(Purpose)
charger grid voltage (low mode) in each copy mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
Sim8-2 MHV(H) COPY
3
5:SUPER PHOTO
3
3
EXEC
[ 1- 8]
3
Setting
Default
range
1-8
3 (–530V)
5 (–580V)
5 (–580V)
5 (–580V)
Disabled
2 (–505V)
Grid Low
–350V
–375V
–400V
–425V
–450V
–475V
–500V
–525V