5.2
Mounting the pressure piece set
5.2.1
General installation information
The installation conditions vary widely. The dead load of the load bearing implement can be
very low or relatively high. You might be dealing with a container, platform or a roller
conveyor. The following installation instructions can therefore only describe the general
procedures.
Always set up the load bearing implement on dummies in order to protect the load cells from
damage during installation.
The load bearing implement then only has to be raised a few millimeters from bracket to
bracket in order to position the pressure piece set. The following description of the
installation is based on this assumption.
Note
Maintenance-friendly design
When planning the layout, ensure that the load cells are easily accessible once they are
installed.
Depending on the installation conditions, the detailed procedure may deviate from the
following description.
5.2.2
Overview
The following actions are required in order to install the pressure piece set.
1. Preparing the load cell
2. Preparing the pressure piece set
3. Installing the load cell with pressure piece set
4. Checking the installation
The actions are described in detail in the following.
See also
Safety information/instructions (Page 21)
CP-S SB
Operating Instructions, 11/2010, A5E03323543B
5.2 Mounting the pressure piece set
Installation
23