Siemens WM12W520IL Gebruiksaanwijzing en installatie-instructies - Pagina 31

Blader online of download pdf Gebruiksaanwijzing en installatie-instructies voor {categorie_naam} Siemens WM12W520IL. Siemens WM12W520IL 48 pagina's.

Siemens WM12W520IL Gebruiksaanwijzing en installatie-instructies
The drain hose at the siphon
is blocked
Switch off the appliance. Pull out the
1.
mains plug.
Loosen the hose clamp. Carefully
2.
remove the drain hose; residual
water may leak out.
Clean the drain hose and siphon
3.
connecting piece.
Re-attach the drain hose and secure
4.
the connection point using the hose
clamp.
Filter in the water supply
blocked
First, reduce the water pressure in the
supply hose:
Turn off the tap.
1.
Select any programme (except
2.
Rinse/Spin/Empty).
Press the Ü button. Allow the
3.
programme to run for approximately
40 seconds.
Press the # button. The appliance is
4.
switched off.
Pull out the mains plug.
5.
Cleaning and maintenance
Then clean the filter:
Disconnect the hose from the tap.
1.
Clean the filter with a small brush.
For standard and Aqua-Secure
2.
models, clean the filter on the rear of
the appliance:
Remove the hose from the rear of
the appliance.
Use pliers to remove the filter and
then clean it.
Connect the hose and check for
3.
leaks.
en
31