Cisco Meraki CW9163E Installatiehandleiding - Pagina 5

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Cisco Meraki CW9163E. Cisco Meraki CW9163E 28 pagina's.

Cisco Meraki CW9163E Installatiehandleiding
Note: The CW9163E will operate utilizing 802.3af in degraded mode. Please reference the power table below for the expected performance.
Powering Options:
Power
PoE
Eth0
mode
Class
1
AF
1 Gbps
2
AT
2.5 Gbps
Mount plate attachment slots
The mounting slots located on the rear shell of the CW9163E marry to the 4 mounting posts on the mounting plate, securely fastening the CW9163E to the
mounting plate.
Grounding post
The grounding post is located on the left side of the CW9163E unit. Using the included grounding lug, ground the unit to mitigate lightning and other adverse
electrical events.

Factory reset button

Using a flathead screwdriver, remove the reset cap to access the reset pinhole. If the pinhole push button is pressed and held for at least five seconds and then
released, the CW9163E will reboot and be restored to its original factory settings by deleting all configuration information stored on the unit.
Understanding the CW9163E mount plate
The MA-MNT-MR-16 mount plate will ship with the installation kit.
MA-MNT-MR-16
2.4GHz
5GHz
6GHz
off
1x1
1x1
2x2
2x2
2x2
max RF
power
Scan
BLE
ch0/ch1
22 dBm
off
off
21 dBm
on
on
GNSS (tracking)
on
on
5