Argo DD Handleiding voor installatie-instructies - Pagina 7

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Argo DD. Argo DD 16 pagina's. Air conditioner without outdoor unit

Argo DD Handleiding voor installatie-instructies
CAUTION
After the selection of the installation site, according
to the above mentioned points, be sure not to make
holes in areas where electrical wiring or conduits are
located, damaging them.
Make sure that there are no obstacles in the conduits
inside the wall affecting the free circulation of the
external air. The unit must be kept at a minimum
distance of 80 cm from any wall or obstacle.
3.2 - HOW TO INSTALL THE UNIT
CAUTION
Do not mount the front panel and the bottom panel
until installation is complete.
- Apply at the wall the full scale diagram, fix and level it.
- Drill the two holes Ø 162 mm and the hole Ø 35 mm for
the condensate drainage toward the outside (assure a
positive slope toward the outside).
- Cut to size the supplied plastic sheets in order to obtain,
by rolling them, two tubes of the right size (it is necessary
to measure the thickness of the wall and subtract 70 mm
in order to leave enough space to the grilles).
FULL SCALE DIAGRAM
1013
A
C
355
7
Level
Mill
A Holes for rawl plugs Ø 9 mm
B Hole for electrical connection Ø 30 mm
C Holes for air Ø 162 mm
D Hole for condensate discharge Ø 35 mm
C
205
D
Full scale
diagram
B
EN