1 POWER indicator
Lights as follows to show the power-supply status.
Green: Power is supplied to the BVP-900/900P.
Red: The CAMERA POWER switch of the CCU-
700A/700AP is set to the off position, or the CAM
PW button of the MSU-700 or RCP-700-series unit
is set to off.
Yellow: Power is supplied to the BVP-900/900P,
however the VF PW button of the MSU-700 or
RCP-700-series unit is set to off and power is not
supplied to the viewfinder.
Not lit: Power is not supplied to the camera.
2 Video signal select buttons
Select the video signals (R, G, and B) displayed on the
viewfinder.
When the TEST OUT switch on the internal MS board
is set to VF, the TEST OUT connector outputs the
same signals as those displayed on the viewfinder.
• The R, G, and B buttons can be pressed together or
separately and the signals corresponding to the
pressed buttons are output. When two buttons are
pressed, the corresponding signals are mixed and
then output.
• When the R, G, and B buttons are pressed at the
same time, a Y signal is output to the viewfinder and
the TEST OUT connector.
• When no button is pressed, the following signals are
output:
When a black-and-white viewfinder is used: A Y
signal is output to the viewfinder and the TEST
OUT connector.
When a color viewfinder is used: The R, G and B
signals are output to the viewfinder, and a color
picture appears on the viewfinder. The TEST
OUT connector outputs a Y signal.
3 H-POSI (horizontal position) control
Adjusts the horizontal position of the box cursor on the
viewfinder screen.
4 V-POSI (vertical position) control
Adjusts the vertical position of the box cursor on the
viewfinder screen.
5 WIDTH control
Adjusts the width of the box cursor on the viewfinder
screen within the safety zone.
See description of the SAFETY ZONE switch.
6 HEIGHT control
Adjusts the height of the box cursor on the viewfinder
screen within the safety zone.
See description of the SAFETY ZONE switch.
7 RET (return video) button
Press this button when another return video system is
used, then the return video signal selected at the
RETURN SELECT knob can be monitored on the
viewfinder screen. When the TEST OUT switch on
the MS board is set to VF, the TEST OUT connector
also outputs the selected return video signal. If you
press this button again, the camera's video signal is
output to the viewfinder and the TEST OUT
connector.
8 RET 1 (return video 1) button
• Press to monitor the return video 1 signal on the
viewfinder screen. When the TEST OUT switch on
the MS board is set to VF, the TEST OUT connector
also outputs the return video 1 signal. If you press
this button again, the camera's signal is again output
to the viewfinder and the TEST OUT connector.
• When using the BVP-900/900P as a stand-alone
camera, the playback signal on a VTR is output.
Notes
• The RET 1 button has priority over the RET button if
both buttons are pressed. (The TEST OUT switch
setting has no effect on the priority.)
• When the TEST OUT switch is set to RET, the TEST
OUT connector outputs the return video signal
regardless of the setting of the video signal select
button.
9 RETURN SELECT knob
Selects a return video signal on the viewfinder screen
when the RET button is depressed.
!º Back tally lamp
Lights when a red tally signal is supplied. When the
CALL button on the MSU-700 or RCP-700-series unit
is pressed, the lamp lights if it is not lit, and goes out if
it is lit. You can adjust the brightness of the tally lamp
using the control on the internal AT board.
Attach the supplied number plate (0 through 9) to
show the camera number.
For details on adjusting the brightness and attaching a
number plate, refer to the System Manual.
9 (E)