High & Low Records
High and low records reflect the minimum and maximum temperature and
humidity recorded since the unit was powered on, since the batteries were
replaced, or since the records were manually reset (whichever was most
recent).
To view the LOW records, press and release the " " button. The low record
indicator appears on the display next to the low records.
To view the HIGH records, press and release the " " button. The high record
indicator appears on the display next to the high records.
To reset the LOW records, press AND HOLD the " " button while viewing the
low records. Dashes will display to confirm all low records have been reset.
To reset the HIGH records, press AND HOLD the " " button while viewing
the high records. Dashes will display to confirm all high records have been
reset.

Calibration

The indoor/outdoor temperature and humidity readings, and barometric pressure can
be calibrated on the display unit to improve accuracy. Calibration can improve accuracy
when sensor placement or environmental factors impact the data accuracy.
1. To access calibration mode, press AND HOLD the "
buttons simultaneously for at least 5 seconds.
2. To adjust the currently selected (flashing) item, press and release the "
buttons to calibrate the data value higher or lower than the actual reading.
3. To save your adjustments, press and release the " OK " button to adjust the next
preference. The "
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)*
*To change from AUTO to MANUAL pressure mode and vice versa, press
AND HOLD the " " button for 10 seconds. "auto" will disappear above the
barometric pressure to indicate that manual mode has been activated. Press and
HOLD the " " button for 10 seconds to return to AUTO mode.
After 10 seconds of inactivity, the display will save the adjustments and exit
calibration mode. Note: Calibrations will be erased if the display is reset or if
batteries are removed and the power adapter is unplugged.
" icon will remain illuminated next to calibrated values.
," " OK ," and "