DIGITEN DTC-102 Handmatig - Pagina 6

Blader online of download pdf Handmatig voor {categorie_naam} DIGITEN DTC-102. DIGITEN DTC-102 10 pagina's.

DIGITEN DTC-102 Handmatig
Note: If no entries are made for 30 seconds while programming is in progress, the control
reverts to the normal temperature display.
Set Other Functions
Long press the SET button about 3 seconds until LCD display
1.
Press
and
2.
Short press SET button to set next function.
3.
Long press SET button to save and exit.
4.
After setting, Csp value and Hsp value will show the result that it could confirm whether you
have set up correctly.
Csp(Cooling start point) =SV(set value) +CD (cooling differential)
Hsp(Heating start point)=SV(set value)-HD(heating differential)
Note: Please do not connect any load (heating or cooling equipment) before you set
parameters.
How to restore default settings
Keep pressing SET key until connect the power to this device, controller will restore factory
setting after BI-BI-BI sound.

Function range and setting

CODE
SV
HD
CD
AH
AL
DP
CA
CF
to adjust the temperature
Function
Temperature
va
lue
Heating Differential
Cooling Differential
High
Temperature
Alarm
Low Temperature Alarm -40-120 ℃
Time
of
Compressor
Delay Starting
Temperature Calibration -15-15 ℃
Temperature Unit
Setting Range
Setting
-40-120 ℃
-40-248 ℉
0.3-15 ℃
1-30 ℉
0.3-15 ℃
1-30 ℉
-40-120 ℃
-40-248 ℉
-40-248 ℉
0~10minutes
-15-15 ℉
℃/℉
- 4 -
Default Setting
25 ℃
77 ℉
2.0 ℃
3.0 ℉
2.0 ℃
3.0 ℉
120 ℃
248 ℉
-40 ℃
-40 ℉
3minutes
0 ℃
0 ℉