Cisco ONS 15454 SDH Procedurehandleiding - Pagina 9

Blader online of download pdf Procedurehandleiding voor {categorie_naam} Cisco ONS 15454 SDH. Cisco ONS 15454 SDH 22 pagina's. Install cards and fiber-optic cable

Cisco ONS 15454 SDH Procedurehandleiding
Chapter 2 Install Cards and Fiber-Optic Cable
Table 2-3
XC Card Type
XC-VXL-2.5G
XC-VXC-10G/XC-VXL-10G
Refer to the card's reference section in the "Optical Cards" chapter of the Cisco ONS 15454 SDH
Reference Manual for more information about slot and bandwidth restrictions.
Open the card latches/ejectors.
Step 2
Use the latches/ejectors to firmly slide the optical card along the guide rails until the card plugs into the
Step 3
receptacle at the back of the slot.
Verify that the card is inserted correctly and close the latches/ejectors on the card.
Step 4
Note
Note
Verify the LED activity:
Step 5
The red FAIL LED turns on for 20 to 30 seconds.
The red FAIL LED blinks for 35 to 45 seconds.
All LEDs blink once and turn off for 5 to 10 seconds.
The ACT or ACT/STBY LED turns on. The signal fail (SF) LED can persist until all card ports
connect to their far-end counterparts and a signal is present.
Note
If the card does not boot up properly, or the LED activity does not mimic
Step 6
When a physical card type does not match the type of card provisioned for that slot in CTC, the card
might not boot. If an optical card does not boot, open CTC and verify that the slot is not provisioned
for a different card type before assuming the card is faulty.
If the red FAIL LED does not turn on, check the power.
If you insert a card into a slot provisioned for a different card, all LEDs turn off.
If the red FAIL LED is illuminated continuously or the LEDs behave erratically, the card is not
installed properly. Remove the card and repeat Steps
78-18118-01
Maximum Bandwidth by Shelf Slot for the MRC-12 in Different Cross-Connect
Configurations
It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
If you install the wrong card in a slot, complete the
procedure on page
2-21.
The booting STM-N card will send an AIS-L to the far-end receiver as long as it is
Locked-enabled, disabled.
NTP- D16 Install STM-N Cards and Connectors
Maximum Bandwidth in Slots 1
through 4 and 12 through 17
OC-48
OC-48
"NTP-D227 Remove and Replace a Card"
2
to 5.
Cisco ONS 15454 SDH Procedure Guide, R8.5
Maximum Bandwidth
in Slots 5, 6, 12, or 13
OC-48
OC-192
Step
5, check the following:
2-9