2. Installation

2.5 Teach Pendant Connection

(1) Disconnect the Bypass Plug connected to the Operator Panel.
(2) Connect the connector of the Teach Pendant to the Operator Panel and secure it
tightly.
Make sure to screw in the connector tightly to ensure dust-proof and drip-proof
NOTE
performance.
(3) Make sure that the Teach Pendant starts up.
(4) Make sure that the EMERGENCY STOP switch of the Teach Pendant
operates.
NOTE
When nothing is connected to the TP/OP port of the Controller, the Controller status
will be Emergency Stop status. Connect the bypass plug when the Teach Pendant or
the Operator Panel is not connected.
Connect and disconnect of the Teach Pendant is available when the Controller in
NOTE
ON.
Make sure to disconnect while the Controller power in OFF.