Forensic LabDock S5 and U5 User Manual
For USB, there are three ways to connect:
• If your motherboard has an available 10-pin USB header, use the "USB B-type to 10-pin header"
cable.
• Use a USB B-type to B-type cable to connect to a USB host card.
• Use a USB B-Type to A-type cable and attach the A-type end to an available USB port on your com-
puter.
For SATA:
• Connect a SATA data cable to the rear of the Forensic LabDock and the other end to an available port
on your write-blocked RedPort SAS HBA card.
STOP!
Connecting the pass-through port to any host other than a RedPort card will result in the corre-
sponding front panel port becoming read/write rather than write-blocked.
e. Use the provided screws to secure the Forensic LabDock into the 5.25" drive bay.
NOTE
Using screws other than the provided mounting screws may put pressure on the drive cubby, making
it difficult to insert and remove drives from it. Always use the provided mounting screws where pos-
sible.
Your Forensic LabDock is now ready to use!
2.3 CONNECTING HARD DRIVES TO THE FORENSIC LABDOCK
2.3.1 SATA Hard Drives
a. Insert the hard drive into the cubby. Face the power and data connection side outward.
b. Attach the included SATA data/power connector to the rear of the drive.
c. Connect the 4-pin power cable on the SATA data/power connector to the power port on the front of
the Forensic LabDock.
d. Connect the eSATA data cable of the SATA data/power connector to the write-blocked eSATA port
next to the power switch on the front of the Forensic LabDock.
e. Flip the power switch to the 1 position to power the Forensic LabDock on.
2.3.2 IDE (PATA) Hard Drives
a. Insert the hard drive into the cubby. Face the power and data connection side outward.
b. Attach the included appropriately-sized IDE cable and the included 40-pin legacy Molex power cable
to your hard drive. Both connectors are keyed to fit only one way.
c. Remove any eSATA connector from the eSATA port next to the power switch on the front of the
Forensic LabDock. IDE/PATA drives cannot be recognized if a SATA connection is detected.
d. Connect the other ends of the IDE cable and the 40-pin legacy Molex power cable to the appropriate
write-blocked ports on the front of the Forensic LabDock.
e. Flip the power switch to the 1 position to power the Forensic LabDock on.