Ariston microSYSTEM 15 RFFI Handleiding voor installatie-instructies - Pagina 5
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Ariston microSYSTEM 15 RFFI. Ariston microSYSTEM 15 RFFI 20 pagina's. Type c boilers
Ook voor Ariston microSYSTEM 15 RFFI: Gebruikershandleiding (16 pagina's), Onderhoudsinstructies (24 pagina's)
2.3
S
A
ITING THE
PPLIANCE
Installation should also comply with the following British Standard Codes of Practice:
BS 7593
Treatment of water in domestic hot water central heating
systems
BS 5546
Installation of hot water supplies for domestic purposes
BS 5440-1
Flues
BS 5440-2
Air supply
BS 5449
Forced circulation hot water systems
BS 6798
Installation of gas fired hot water boilers of rated input not
exceeding 60kW
BS 6891
Installation of low pressure gas pipe up to 28mm
BS 7671
IEE wiring regulations
BS 7074
Specification for expansion vessels
BS 5482
Installation of L.P.G.
and in the Republic of Ireland in accordance with the following Codes of Practice:
I.S. 813
Domestic Gas Installations
The following BS Standards give valuable information;
BS 5546
Installation of hot water supplies for domestic purposes
BS 5449
Forced circulation hot water systems
BS 7074
Specification for expansion vessels
BS 7593
Treatment of water in domestic hot water central heating
systems
WARNING!!
The addition of anything that may interfere with the normal operation of the appliance
without express written permission of the manufacturer or his agent could invalidate
the warranty. In GB this could also infringe the GAS SAFETY(Installation and Use)
REGULATIONS.
In the Republic of Ireland the installation and initial start up of the appliance must be
carried out by a Competent Person in accordance with the current edition of I.S.813
"Domestic Gas Installations", the current Building Regulations, reference should also
be made to the current ETCI rules for electrical installation.
The appliance may be installed in any room or indoor area, although particular
attention is drawn to the requirements of the current I.E.E. Wiring Regulations, in
Scotland, the electrical provisions of the Building Regulations applicable in Scotland,
and in the Republic of Ireland, the current edition of I.S.813, with respect to the
installation of the combined appliance in a room containing a bath or shower. The
location of the boiler in a room containing a bath or shower should only be
considered if there is no alternative.
Where a room-sealed appliance is installed in a room containing a bath or
shower reference should be made to the relevant requirements.
In GB this is the current I.E.E. WIRING REGULATIONS and BUILDING
REGULATIONS. In IE reference should be made to the current edition of I.S.813
and the current ETCI rules.
If the boiler is to be sited into a timber framed building, reference must be made to
the current edition of the Institution of Gas Engineers Publication IGE/UP/7 (Gas
Installations in Timber Framed Housing).
The location must permit adequate space for servicing and air circulation around the
appliance as indicated in Section 2.5.
The location must permit the provision of an adequate flue and termination.
For unusual locations special procedures may be necessary.
BS 6798-1987 gives detailed guidance on this aspect.
A compartment used to enclose the appliance must be designed specifically for this
purpose. No specific ventilation requirements are needed for the installation within a
cupboard.
5