5.5 Configuration 
5.5.1 Set  Command   
The Set Command used to set the value of configuration parameter(s), command format: 
Serial API: (refer to the below form) 
HOST‐>ZW: REQ | 0xf2 |  Parameter Number  | size |  Value 
ZW‐>HOST: RES | 0xf2 | RetVal  
 
REQUEST: 
7  
6  
                                                                  Command = 0xF2 
Default                                                     Size
                                                                  .........
  
Parameter Number (8 bits)  
The parameter number field specifies which configuration parameter is being set. The parameter numbers refer to 
the form at the end of the document. 
Default (1 bit)  
If the default bit is set to 1 the device is set to default factory setting and the configuration values is ignored. If the 
default bit is set to 0 then the configuration values is used.  
Size (7 bits)  
The size field indicates the number of bytes used for the configuration value.  
Value 1 ... Value N (variable)  
5  
4  
Parameter Number 
Value 1(MSB)
Value 2
Value n(LSB)