Ariston A45V Reparatiehandleiding - Pagina 9

Blader online of download pdf Reparatiehandleiding voor {categorie_naam} Ariston A45V. Ariston A45V 11 pagina's.

Ariston A45V Reparatiehandleiding

8. SIDE PANELS

Fig. 8-1
• To remove the Side Panels, remove the Four (4) Phillips screws that mount the Panel to the Frame. There are three (3) screws
located along the rear frame edge and a single screw located in the middle of the bottom panel (Fig. 8-1). When removing the
panel note the three (3) alignment pegs along the front frame edge that secure the Side Panel to the Front Frame (Fig.8-2). With
the Right Side Panel removed you now have access to the Main Motor and Drum Belt (Fig. 8-3).

9. MAIN MOTOR

• To access the Main Motor (Fig 9-2), first remove the Rear Access Panels as described in Section 7, then remove the Right Side
Panel as described in Section 8. To replace the Main Motor, remove the three (3) 8mm bolts securing the Blower Fan Blade to the
Motor Shaft (Fig. 9-1), then disengage the Drum Belt from the Pulley Wheels (A) (Fig 9-2). The Motor is held to the Motor Mounts
with six (6) 8mm Bolts, two (2) front and four (4) rear. With the bolts removed the Motor will slide out from the Motor Mount.
REPAIR MANUAL
Fig. 9-1
Fig. 8-2
A
A 45 V
Fig. 8-3
Fig. 9-2
Page: 6