NOTE: The wire leads for the Return Air
Heater and the Auxilliary Return
Air Heater elements are located
inside the freezer thermostat con-
trol box. The wire leads for the
"regular" element are one (1) red
and one (1) white. The wire
leads for the auxilliary element
are both black.

Accessing Component in the Refrigerator Section

Removing the Cold Air Inlet Damper
The cold air inlet control damper is located at the
top center of the refrigerator section. This as-
sembly contains a mechanical thermostat that
operates a dampening door to regulate the flow
of cold air into the refrigerator compartment.
1. Remove the damper control knob.
2. Press in on the two (2) side tabs securing the
control cover to the back panel of the
refrigerator section. (Fig. 18) Then, tip the
control cover forward and pull it up to dislodge
the two (2) tabs at the bottom.
3. Remove the Styrofoam insert and the
two (2) screws securing the damper
control assembly to the back panel
of the refrigerator compartment. (Fig. 19)
Damper
Insert
Screw
Fig. 19
13
Thermostat
Screw
Damper
Insulation
Damper Control
Tab
Screw
Ground Wire
Screw
Screw
Fig. 17
Damper Control Cover
Cover Seen
From Inside
Fig. 18
Tabs
Damper Control
Assembly
Tab