eControls Comfort 365 C365T11 Installateurshandleiding - Pagina 7
Blader online of download pdf Installateurshandleiding voor {categorie_naam} eControls Comfort 365 C365T11. eControls Comfort 365 C365T11 8 pagina's.
14 Night Level LCD Backlight
Factory Default: On. Range: On or Off.
The LCD has a low level backlight that can be used as a night light.
Touch the
UP
key to turn the
low level backlight ON or touch
the
DOWN
key to turn OFF.
Touch
NEXT
to display the
next option, or
ENTER
to save
the option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
15 Airflow Control, On or Off
Factory Default: On. Range: On or Off.
This option turns the automatic airflow control on or off. If on, the
thermostat will automatically adjust the airflow. If off, airflow is disabled.
Touch the
UP
key to select ON
for airflow control or touch the
DOWN
key to select OFF to
disable airflow control.
Touch
NEXT
to display the
next option, or
ENTER
to save
the option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
16 Enable Selecting Manual Airflow Control
Factory Default: Off. Range: On or Off.
This option enables the consumer to override automatic airflow control
for 3 hours. If off, the user will not be able to override automatic airflow
control.
Touch the
UP
key to select ON
to enable manual airflow
control or touch the
DOWN
key
to select Off so that manual
airflow control is not an option.
Touch
NEXT
to display the next
option, or
ENTER
to save the
option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
For options 17 - 20, use the installer test o
determine the max
imum allowable airflow.
17 Maximum Upstairs Airflow in Heating
Factory Default: 150%. Range: 100% to 160%.
Touch the
UP/DOWN
keys to
select the maximum allowable
upstairs airflow in heating.
Touch
NEXT
to display the next
option, or
ENTER
to save the
option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
Option
Night
NEXT
ENTER
Upstairs
Option
Airflow %
Downstairs
NEXT
ENTER
Option
NEXT
ENTER
n pages 7-8 to
Upstairs
Option
Heat
Airflow %
Downstairs
NEXT
ENTER
18 Maximum Upstairs Airflow in Cooling
Factory Default: 140%. Range: 100% to 160%.
Touch the
UP/DOWN
keys to
select the maximum allowable
upstairs airflow in cooling.
Touch
NEXT
to display the
next option, or
ENTER
to save
the option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
19 Maximum Downstairs Airflow in Heating
Factory Default: 150%. Range: 100% to 160%.
Touch the
UP/DOWN
keys to
select the maximum allowable
downstairs airflow in heating.
Touch
NEXT
to display the
next option, or
ENTER
to save
the option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
20 Maximum Downstairs Airflow in Cooling
Factory Default: 140%. Range: 100% to 160%.
Touch the
UP/DOWN
keys to
select the maximum allowable
downstairs airflow in cooling.
Touch
NEXT
to display the
next option, or
ENTER
to save
the option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
21 Maximum Temperature Differential
o
Factory Default: 2 F.
Range: 0 to 10 F
This the maximum allowable temperature difference between the
upstairs and downstairs temperatures. When the temperature
difference is equal to or greater than the allowed differential, the airflow
is adjusted.
Touch the
UP/DOWN
keys to
select the maximum allowable
temperature difference between
the upstairs and downstairs.
Touch
NEXT
to display the next
option, or
ENTER
to save the
option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
22 Factory Restore
Touch NEXT or
ENTER
to
return to normal thermostat
operation. Touch the hidden
BACK key to return to previous
option.
To restore factory settings,
touch ENTER, then touch the
UP key.
7
Upstairs
Option
Airflow %
Cool
Downstairs
NEXT
ENTER
Upstairs
Option
Heat
Airflow %
Downstairs
NEXT
ENTER
Upstairs
Option
Airflow %
Cool
Downstairs
NEXT
ENTER
o
o
Upstairs
Option
Airflow %
Downstairs
NEXT
ENTER
WARNING! Factory Restore
resets ALL settings.
Option
NEXT
ENTER