Zanussi ZEE6940 Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Zanussi ZEE6940. Zanussi ZEE6940 16 pagina's. Product manaul
Ook voor Zanussi ZEE6940: Gebruikershandleiding (36 pagina's), Gebruikershandleiding (48 pagina's), Gebruikershandleiding (40 pagina's), Gebruikershandleiding (12 pagina's)

Zanussi ZEE6940 Gebruikershandleiding
The minimum distance of 100 mm must be left
between the side edges of the cut out and ad-
jacent cabinets or walls.
The minimum distance (in line) between the
edges of the hob and flammable materials
above the hob is 400 mm. If the distance is
smaller, separate the flammable materials from
the edges of the hob by a minimum of 50 mm
Do not fit a cooker hood or combustible materi-
al lower than 650 mm above the hob.
For appliances installed in the Republic of Ire-
land please refer to NSAI- Domestic Gas In-
stallation I.S 813 Current Edition Section 7-
Permitted Locations of Appliance.
Installation
Warning! Read and follow the
instructions carefully. There is a risk of
injury or damage to the appliance.
• Make sure that there is no damage to the ap-
pliance from the transportation. Do not con-
nect a damaged appliance. Speak to the
supplier if necessary.
• Install built-in appliances only after you as-
semble the appliance into correct built-in
units and work surfaces. Make sure that
built-in units and surfaces obey the stand-
ards.
• Obey all orders and standards in force in the
country where you use the appliance (safety
standards, recycling standards, electrical
safety standards etc.)
Warning! Risk of injury from electrical
current.
• The electrical mains terminal is live.
• Make electrical mains terminal free of volt-
age.
• If the fixing bracket is near to the terminal
block, do not let the connection cable come
in contact with the edge of the bracket.
Electrical connection
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug (if
applicable).
www.zanussi.com
• The appliance must not be connected with
an extension cable, an adapter or a multiple
socket. There is a risk of fire.
• Do not let the power cable to heat up to a
temperature of more than 90° C. The cable
should be guided by means of clamps fixed
to the side of the cabinet, in order to avoid
any contact with the equipment beneath the
cooktop.
Electrical Requirements
Permanent electrical installation must agree
with the latest I.E.E. Regulations and local Elec-
tricity Board regulations. For your own safety
the installation must be done by a qualified
electrician (e.g. your local Electricity Board, or a
contractor who is on the roll of the National In-
spection Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer refuses to be held re-
sponsible, if these safety measures are not
abided by.
Supply connections:
This hob has to be connected to 230 — 240 V
( 50 Hz) electricity supply.
The hob has a terminal block which is
marked as follows:
• L or 1 — Live terminal
• N or 4 — Neutral terminal
or E or 5 — Earth terminal
Before carrying out the connection, make sure:
1. The limiter valve and the electrical system
can take the appliance load (see the rating
plate)
2. The supply system is equipped with an effi-
cient earth connection in compliance with
the current standards and regulations
3. The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
You must purchase and install the power cable.
Use only a connection cable of type H05V2V2-
F T90 or its equivalent. Make sure that the ca-
9