Please ensure that when the appliance
is installed it is easily accessible to an
engineer in the event of a breakdown.
All installation must comply with the
local authorities requirements for
the discharge of exhaust air.
Incorrect installation may affect the
safety of this cooker hood.
Installation Requirements
Before installation, check that the
wall to which the cooker hood is to
be fitted for electricity cables and
water and gas pipes.
This cooker hood is designed to be fixed to
any rigid vertical surface over a cooking
area, and can be used in the extraction
(ducted to the outside) or re-circulation
(internal recycling) mode.
The installation work must be carried out
by a qualified electrician or competent
person.
The manufacturer declines any
responsibility for damages due to incorrect
installation of the cooker hood or if the
cooker hood is not installed in compliance
with relevant regulations controlling this
type of installation.
This appliance can be used in either a
ducting or filtering mode.
Ducting (fig.1) – Cooking vapours and/or
odours are passed straight outside (ceiling
and/or wall) via a disposal duct, using the
holes that are on the top and/or the back
of the appliance.
Filtering (fig.2) – Cooking vapours and/or
odours are removed from the air by 2
charcoal filters and the air is then re-
circulated around the room from the front
vents.
ATTENTION: For the filtering option it is
absolutely necessary to use the charcoal
filters but not for the ducting option.

INSTALLING THE COOKER HOOD

1
2
Charcoal filters are available from your
local Zanussi Service Force Centre:
Part No. 942 640 157
9