Safety Precautions
STORE THE AIR COMPRESSOR PROPERLY: When not in use the air compressor should
be stored in a secure, dry place out of the reach of children. Always lock up the
storage area.
PROTECT YOUR HEARING: Ear protection should be worn when operating this
compressor.
MAINTAIN THE AIR COMPRESSOR WITH CARE: If the air compressor is damaged in
any way, have it repaired by a qualified service engineer.
EXTENSION LEAD: Only use extension leads that are of an appropriate power rating
and suitable for the work environment. Extension leads must have an earth
connection. Inspect the extension lead regularly and replace if damaged.
ONLY USE PARTS AND ACCESSORIES RECOMMENDED IN THIS MANUAL: The use of
unauthorised accessories or attachments is not permitted and may result in
personal injury and damage to the air compressor. Do not attempt to repair or
modify the air compressor.
STAY ALERT: Watch what you are doing, use common sense, and do not operate
the air compressor when you are tired. The air compressor should not be used if
you are under the influence of alcohol, drugs or any medication that makes you
drowsy.
BEFORE EACH USE CHECK THE AIR COMPRESSOR AND HOSE FOR DAMAGED PARTS:
Never use the air compressor if it has been damaged in any way. Have the air
compressor repaired by a qualified service engineer. Do not use the air compressor
if the On/Off switch does not operate correctly.
HANDLE THE AIR COMPRESSOR CAREFULLY: Operate the air compressor according
to the instructions contained within this instruction booklet. This air compressor
should never be operated by children or individuals unfamiliar with its operation.
KEEP THE MOTOR AIR VENT CLEAR: Keep the motor vent clear and free from dust,
wipe regularly to maintain an adequate supply of clean air to the air compressor.
OPERATE THE AIR COMPRESSOR AT THE CORRECT VOLTAGE: Make sure that the
mains supply voltage is the same as the voltage shown on the rating plate.
DO NOT WIPE THE PLASTIC PARTS WITH SOLVENT: Do not use solvents or thinners
such as petrol, benzene, carbon tetrachloride or alcohol to clean the air
compressor, as these chemicals will damage the finish. With the air compressor
unplugged from the supply, use a dry cloth to wipe over the plastic casing.
6
Routine Maintenance
Every six months
•
Make sure that all bolts are securely tightened.
Check the cylinder head bolts and motor housing screws and if any have
worked loose retighten to 8.8Nm
max. (6.5lbf ft).
• Clean all the external parts of the
compressor.
Oil
After the first 100 hours use, replace the
oil completely using Clarke SAE40
compressor oil. Then replace the oil after
every 500 hours of operation or every 6
months.
To empty the oil from the machine,
remove the oil drain plug from the
crankcase cover. See figure 12.
Non Return Valve
Examine the non-return valve, and
replace the gasket and valve if
necessary
Figure 12
Figure 13
Figure 14