Clarke CRWP1 Gebruiksaanwijzing - Pagina 3

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Clarke CRWP1. Clarke CRWP1 4 pagina's. Semi-rotary hand pump

Clarke CRWP1 Gebruiksaanwijzing
5. Connect any inlet and discharge hose connectors which are compatible
with the 1" BSP connecting flanges of the pump.
MAINTENANCE
1. Ensure that the seal compression nut (3) is sufficiently tight. If not, leakage
can take place from the pump handle shaft.
2. If using the pump for water, and there is a likelihood of freezing when not
in use, drain the pump via the access plug (15).
3. If the pump has been used for pumping any liquid likely to leave chemical
residues, it should be flushed through with clean water after use.
4. If the pump will be unused for extended periods, insert some oil through
the access plug (15) to protect the internal parts.
• Ensure the oil used does not contaminate the medium being pumped.
5. Periodically check that all nuts and bolts are tight.
A wide range of accessories are available from your nearest CLARKE dealer,
including hoses and hose adaptors and couplings.
COMPONENT PARTS
1.
HTCRWP101 Flange Bolt & Nut
2.
HTCRWP102 Cover Bolt & Nut
3.
HTCRWP103 Seal Compression Nut
4.
HTCRWP104 Wing Piston, Flap & Shaft 11.
5.
HTCRWP105 Suction Divider, Flaps
6.
HTCRWP106 Handle & Handle Spike
7.
HTCRWP107 Gland Packing Set
8.
HTCRWP108 Gland Ring
9.
HTCRWP109 Shaft End Nut
10.
HTCRWP110 Washer
HTCRWP111 Conn Flange
12.
HTCRWP112 Casing
13.
HTCRWP113 Cover
14.
HTCRWP114 Flange Joint
15.
HTCRWP115 Access Plug
3