ATTENTION:
The appliance must not be used under the following conditions:
in rooms of potentially explosive atmosphere
in rooms of aggressive atmospheres, for example ammonia and wood acid
In rooms with water which shows a pH-value outside of 7,0 to 7,4. Remark: In
The case of lower pH-value, corrosion occurs at all metals and damages occurs
at mortar containing materials. In the case of higher pH-value, it comes to
irritation of skin and eye mucous membrane and extreme lime deposits.
In rooms with salt or salty liquids. Salt content >1% (also sole baths).
In rooms of air treated with ozone
in rooms featuring a high concentration of solvents
in rooms of an extremely high ratio of dust.
Please consider also, that extremely air movings around the dryer can annoy
or affect the function of the dryer as the air flow of the dryer can not flow as
planned.
In the case of doubtful operating conditions it is recommended to contact the
Technical Department of Messrs. AERIAL or a specialized dealer.
Using an AD-air dryer under inadequate operating conditions will entail that
the warranty becomes null and void.

7.Technical data

Among other things, many different components which are installed in the
condensation dryer decide on the capacity of the device. Since these components
can never be completely identical, in accordance to DIN EN 810 the capacity may
deviate up to 5% of specified capacity.
General:
Operation range:
Protection class:
Electrical supply:
Type
Air volume
Power
consumption
Noise level
refrigerant (charge see type
plate)
+3° C up to + 32° C / 40% r.h. up to 95% r.h.
IP 54
230 V / 50 Hz
cbm/h
Max. Watt
dB(A)
page 9 of 13
AD 110
250
198
46
R134a