ESI ESPREE Montage- en bedieningshandleiding - Pagina 6

Blader online of download pdf Montage- en bedieningshandleiding voor {categorie_naam} ESI ESPREE. ESI ESPREE 8 pagina's. Pneumatic table base

ESPREE PNEUMATIC TABLE BASE
STEP 12
With the assistance of a helper, turn the table
upright and place it in its final position.
IMPORTANT: There must be 1" (25mm)
of clearance on all sides of the work
surface (and other moving parts) to
ensure free, unobstructed movement.
• Adjust the leveling glides on the feet
to level the work surface, if necessary.
STEP 13
Test operation.
• Place the contents on the table that
have been specified for the work surface.
The weight of the contents is important when
testing operation.
• Verify that the weight of the work surface and contents is
within the lift rating shown on the bottom of the frame.
• Remove the safety pin. Unsnap the safety ring to remove it and
the warning tag. IMPORTANT: The safety pin and safety ring must
be removed or else the table will not operate.
• Check operation by pulling the release lever toward you with one hand and using the other hand to raise
or lower the table.
WARNING: The table may suddenly raise upward or fall downward when the release lever is pulled. The
table is designed to be balanced when the weight of the work surface and its contents is at the midpoint
of the load rating.
STEP 14
Adjust cable tension, if necessary.
• If the table does not lock into place when the lever is released,
tighten the cable adjustment nut one-half turn and recheck.
• If the table stays locked in one place or moves slowly,
loosen the cable adjustment nut one-half turn and
recheck.
• Call ESI Customer Service if you have questions
about operation or adjustment.
6
Cable
Adjustment
Nut
ASSEMBLY