ClearWater CTA5 Installatie-instructies - Pagina 2

Blader online of download pdf Installatie-instructies voor {categorie_naam} ClearWater CTA5. ClearWater CTA5 3 pagina's. Crystal single lever bath filler, crystal single shroud

Dimension
Installation
MIXER BODY
WASHER
FIXING NUT
FLEXIBLE PIPES
LEFT: HOT FEED
RIGHT: COLD FEED
1: Fit the washer into the groove in the underside of the mixer body.
2: Screw the flexible pipes into the mixer body, and fully hand tighten.
3: Pass the tail of flexible pipes through the hole on the bath from above, and place the mixer in position on the bath, to see if any
alteration to the existing supply pipe work is necessary, make any necessary alterations to the pipe work.
4: Slide the fixing nut up the tails and onto the fixing bolt.
5: Check that the mixer body is correctly positioned, fully tighten the fixing nut.
6: Connect the water supply pipe to the tail of flexible pipes with the hot water on the left and cold water on the right.
Ø55
22
35
HANDLE
NOZZLE
2 - 2
197
108
Ø55
154
2-G3/4
CAP
ALLEN
GRUB
KEY
SCREW
CARTRIDGE
COVER
RETAINING
NUT
CARTRIDGE
MIXER BODY
To remove the cartridge.
First shut off the water supply to the tap.
1: Pull out the cap from the handle.
2: Loosen the grub screw in handle, but do not remove it.
3: Take off the handle, unscrew the cartridge cover.
4: Using a correct size spanner unscrew the retaining nut.
5: Pull the cartridge and wash it with clean running water.
6. Dry and lightly grease the seals (only use silicone grease)
7: Replace them in turn.
HANDLE
A