Once everything has been
connected, turn on the power
to the OZ-SPA unit. Make sure
all the connections are
complete and tight.
After installation and turning on
all the equipment, you will see
a frothing (very tiny milk-like
bubbles) action immediately
after the venturi injector. This is
located on the ¼" clear vinyl
hose. These tiny bubbles
should also appear at the
nearest return line and possibly
other return lines. This means
ozone is getting injected into
the pool's water.
Spa Water Chemistry
To achieve optimal performance from the OZ-SPA system, it is recommended the following be
performed prior to initial start-up:
• BACKWASH or clean filter
• Test and adjust water chemical balance to recommendations in the chart below
The amazing thing you will notice about the OZ-SPA system is the clarity of the water, especially if
you are using the MineralPURE ionization system in conjunction with it.
You might initially notice the water getting cloudy the first couple of days. DO NOT BE ALARMED.
THIS IS NORMAL! You will want to clean or backwash your filter after the first
week.
Visual Inspection
You will want to periodically inspect the power box in the evening to ensure the
unit is functioned correctly. Turn the system on temporarily, if needed. The
indicator light, located next to the output connector will glow a nice blue color.
The ozone unit should only be on when the pump is running.
To insure that the venturi injector and bypass are working correctly, simply
observe to see if small bubbles are entering the pool and the "frothing" effect is
taking place in the clear window of the venturi manifold window.
H. Starting the System
water flow
I. Balancing the Spas Water
pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 - 7.6
Total Alkalinity (TA) . . . . . . . . . . . . . . . 80 - 120 ppm
Calcium Hardness (CH) . . . . . . . . . . . . 150 - 350 ppm
Total Dissolved Solids (TDS). . . . . . . . 300 - 2000 ppm
Copper Ion Levels . . . . . . . . . . . . . . . . 0.15 - 0.2 ppm
J. Periodic Inspection
water flow
6
¼" reinforced vinyl hose
Venturi Injector
¾" ID vinyl tubing
(this side should be
showing very
small bubbles)
"Frothing"
Effect
(small bubbles)
Continue on next page >>>