2. OPERATION
In this manual, we will explain general use of the Fiber Microscope. However, it is important 
toreadthespecific termination instructions published by the manufacturer of the connector you 
are using. Thiswill ensure proper termination. Also, be sure you have read the User Safety 
Warning and fully understandthatdirect eye contact with laser light and magnified laser light 
should be avoided. 
1. Begin by loading the polished connector into the adapter. If you have purchased our 
Universal Adapter,simply slide the connector ferrule(2.5mm)into the hole until you feel it hit a 
stop (see figure3).it mayrequirea little pressure to get it started as our Universal adapter is 
equipped with a no-slip gripping mechanism.it isimportant to slide the connector ferrule all the 
way to the stop. This will minimize any refocusingthat needsto be done when changing from 
one connector to the next. if you have purchased one of thededicatedadapters, insert the 
connector just as you would into a patch bay or mated connector.
2. Now turn the light on.The light operates by pressing and holding the light Switch in .You 
cantell if thelight is on by checking the "Backlight Window"(see figure1). If you see light through 
this window, youareready to work. 
3. Once the connector is loaded and the light is on, hold the eyepiece up to your eye and 
beginfocusing. Unlike many instruments of this type, the Fiber Microscope is always centered so 
there is no alignment tobe done. Grip the focusing adjustment(brass wheel with rubber grip,see 
figure#1) and turn it to. focus the image.The first time you use the microscope, it to focus the 
image.The first time youusethemicroscope, it may take a little longer to find the image. Once 
you find the image, very little re-focusingisnecessary if the connector is properly loaded. 
4. Once you can visualize the connector ferrule, you can evaluate it for polish quality,cleave 
quality, andcleanliness optionally, you can hold the opposite end of a cable to the Backlight 
windowto give furthercontrast to the core. Check with the manufacturer of your connector for 
further instructions. 
3. CHANGING THE LAMP
1. This microscope utilizes a white LED light source. The LED has a stated lamp life of over 100, 
000hours.Therefore, you should never have to change the lamp. if you have problems with 
illumination, please call your sales person to arrange for repair.