INITIAL SET UP & MAINTENANCE
Do not lift the machine by the crimper head. Lift with a fork lift
under the tank.
Mount the crimper on a sturdy surface
Electrical Requirements:
220 Volt 3 Phase Current (Standard)
440 Volt 3 Phase Current (Optional)
Check to be certain that the motor rotates in the direction of the
arrow shown on the motor housing. If motor rotation is opposite of
the direction of the arrow, reverse any two hot wires in the
electrical plug.
Damage to the pump can result if the motor does not rotate in the
correct direction.
Check the oil level in the sight glass on the rear of the crimper. 8
U.S, gallons of ISO 46 hydraulic oil are required to completely
refill the tank.
Oil can be drained from either of the two ports at the bottom of the
tank.
An additional oil cooler, while not normally required, can be
plumbed into the two ports at the rear of the crimper
Front Flange Bolts: Periodically, every 6-12 months depending
upon useage, the front flange bolt torque should be checked. The
correct torque is 330NM (243 Ft Lbs)
Front Flange Bolts