Maintenance

Alvarado recommends performing the maintenance steps below every (60) days. Maintenance should be performed
more frequently in high use applications and/or in dusty or humid environments.
1. Anchoring: Check that the anchors are tensioned to 20 ft-lbs. Tighten if necessary. Clean any accumulated dust
and dirt from the anchors and flange.
2. Leveling: Verify the hinge post and gate arm are horizontally and vertically level. Shim as necessary. Ensure the
gate arm and hinge post form a 90° angle.
3. Overtravel: Check the gate for overtravel. Overtravel is defined as the gate swinging in excess of 90° from the
closed position. Overtravel can lead to the gate arm colliding with adjacent fixtures, potentially causing damage to
the fixture and/or the gate. If the gate overtravels, refer to the Adjusting Swing Limit section on page 6.