3M 51P71 Gebruikershandleiding

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} 3M 51P71. 3M 51P71 2 pagina's.

3M 51P71 Gebruikershandleiding
3
Half Facepiece Respirator Assembly
5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable
User Manual
for 3M™ Organic Vapor Respirator, P95 Assembly 51P71/52P71/53P71
Important: Keep these User Instructions for reference.
GENERAL SAFETY INFORMATION
Intended Use
The 3M™ 5000 Series Half Facepiece Respirators are NIOSH approved and designed to help provide
respiratory protection against certain airborne contaminants when used in accordance with all use instructions
and limitations and applicable safety and health regulations.
This product contains no components made from natural rubber latex.
This respirator helps protect against certain airborne contaminants. Misuse may result
in sickness or death.
TC-
PROTECTIONS
23C-859
OV
84A-0017
OV/P100
84A-4666
OV/P100
84A-1027
OV/P100
84A-4667
OV/P100
84A-1641
OV/P95
84A-2306
OV/HF/P95
84A-2383
OV/P95
84A-0066
OV/P100
84A-0335
OV/N95
84A-1351
OV/P95
23C-865
OV/CL/HC/SD/HF/HS
84A-0019
OV/CL/HC/SD/HF/HS/P100
84A-4668
OV/CL/HC/SD/HF/HS/P100
84A-1029
OV/CL/HC/SD/HF/HS/P100
84A-4669
OV/CL/HC/SD/HF/HS/P100
84A-1643
OV/CL/HC/SD/HF/HS/P95
84A-2308
OV/CL/HC/SD/HF/HS/P95
84A-2385
OV/CL/HC/SD/HF/HS/P95
84A-0068
OV/CL/HC/SD/HF/HS/P100
84A-0337
OV/CL/HC/SD/HF/HS/N95
84A-1353
OV/CL/HC/SD/HF/HS/P95
23C-1768
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM
84A-0544
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P100
84A
84A-4670
4670
OV/C C L/ L/CD/
OV/
CD/HC/
HC/AM
AM/ / M M A/ A/SD/
SD/H H F/ F/HS/
HS/F F M M / / P100
84A-1032
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P100
84A-4671
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P100
84A-1646
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P95
84A-2311
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P95
84A-2388
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P95
84A-0545
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P100
84A-0542
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/N95
84A-1356
OV/CL/CD/HC/AM/MA/SD/HF/HS/FM/P95
1. PROTECTION
P100 - Particulate Filter (99.97% filter efficiency level)
effective against all particulate aerosols.
OV - Organic vapor
AM - Ammonia
HS - Hydrogen sulfide
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs.
J - Failure to properly use and maintain this product could result in injury or death.
K - The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this respirator when used against formaldehyde
L - Follow the manufacturer's User's Instructions for changing cartridges, canister and/or filters.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer .
O - Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
1.
2.
5.
6.
WWARNING
THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
RESPIRATOR COMPONENTS
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
P100
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
P95 - Particulate Filter (95% filter
N95 - Particulate Filter (95% filter efficiency level) effective
efficiency level) effective against all
against particulate aerosols free of oil; time use restrictions may
particulate aerosols.
apply.
CL - Chlorine
CD - Chlorine dioxide
MA - Methylamine
SD - Sulfur dioxide
FM - Formaldehyde
3.
3
7.
CAUTIONS AND
2
LIMITATIONS
ABCHJLMNO
ABCHJLMNOP
ABCHJLMNOP
X
X
ABCHJLMNOP
X
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
ABCHJLMNO
ABCHJLMNOP
ABCHJLMNOP
X
X
ABCHJLMNOP
X
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
X
ABCHJLMNOP
ABCHJKLMNO
ABCHJKLMNOP
A A BCHJKLM
BCHJKLMN N OP
OP
X
X
ABCHJKLMNOP
X
X
ABCHJKLMNOP
X
ABCHJKLMNOP
X
ABCHJKLMNOP
X
ABCHJKLMNOP
X
ABCHJKLMNOP
X
ABCHJKLMNOP
X
ABCHJKLMNOP
HC - Hydrogen chloride
HF - Hydrogen fluoride
4.
8.
USE INSTRUCTIONS AND LIMITATIONS
3M™ 5000 Series Respirators are manufactured as
integral assemblies and the chemical cartridges are
not replaceable. Do not use if the cartridges have
been removed.
Failure to follow User Instructions may result in
sickness or death.
Important
Before use, wearer must read and understand these
User Instructions. Keep these User Instructions for
reference.
Use For
Respiratory protection from certain organic vapors
according to NIOSH approvals, OSHA standards, in
Canada CSA standard Z94.4-93 requirements, other
applicable regulations and 3M instructions. When
3M™ 5P71 (O7194) P95 Particulate Filters are
attached, use for solid and liquid aerosol including
oils, such as metal fumes produced from welding,
brazing, cutting and other operations involving
heating of metals; paint spray; pesticides.
Do Not Use For
Concentrations of contaminants which are
immediately dangerous to life or health, are
unknown or when concentrations exceed 10 times
the permissible exposure limit (PEL) or according to
specific OSHA standards or applicable government
regulations, whichever is lower. Asbestos.
Sandblasting.
Use Instructions
1. Failure to follow all instructions and limitations
on the use of this respirator and/or failure to
wear this respirator during all times of exposure
can reduce respirator effectiveness and may
result in sickness or death.
2. Before occupational use of this respirator, a
written respiratory protection program must be
implemented meeting all the requirements of
OSHA 29 CFR 1910.134 such as training, medical
evaluation, and fit testing and applicable OSHA
substance specific standards. In Canada, CSA
standard Z94.4-93 requirements must be met.
3. The airborne contaminants which can be
dangerous to your health include those that you
may not be able to see or smell.
4. Leave the contaminated area immediately
and contact supervisor if you smell or taste
contaminants or if dizziness, irritation, or other
distress occurs.
5. Store the respirator away from contaminated
areas when not in use.
6. Dispose of used product in accordance with
applicable regulations.
Use Limitations
1. This respirator does not supply oxygen. Do not
use in atmospheres containing less than 19.5%
oxygen.
2. Do not use when concentrations of contaminants
are immediately dangerous to life or health,
are unknown or when concentration exceed
10 times the permissible exposure limit (PEL)
or according to specific OSHA standards or
applicable government regulations, whichever is
lower.
3. Do not alter, abuse or misuse this respirator.
Do not clean using destructive methods such as
vacuum, wash, compressed air, etc.
4. Do not use with beards or other facial hair
or other conditions that prevent a good seal
between the face and the faceseal of the
respirator.
Time Use Limitation
1. If respirator becomes damaged, soiled,
or breathing becomes difficult, leave the
contaminated area immediately and dispose of
the respirator.
2. Replace respirator in accordance with an
established change schedule or earlier if smell,
taste or irritation from contaminants is detected.
If used in environments containing only oil
aerosols, dispose of filters after 40 hours of use
or 30 days, whichever is first.
NIOSH Cautions and Limitations
The following restrictions may apply. See NIOSH
approval label.
A– Not for use in atmospheres containing less than
19.5 percent oxygen.
B– Not for use in atmospheres immediately
dangerous to life or health.
C– Do not exceed maximum use concentrations
established by regulatory standards.
H– Follow established cartridge and canister
change schedules or observe ESLI to ensure
that cartridge and canisters are replaced before
breakthrough occurs.
J– Failure to properly use and maintain this product