ASHAPOWER NEON-30 Gebruikershandleiding - Pagina 12

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} ASHAPOWER NEON-30. ASHAPOWER NEON-30 14 pagina's. Solar mppt charge controller
Ook voor ASHAPOWER NEON-30: Gebruikershandleiding (14 pagina's)

ASHAPOWER NEON-30 Gebruikershandleiding
Note: Before changing the default settings values of the device, ensure the maximum ampere
and voltage ratings applicable for your battery type (SMF,LEAD ACID etc) and brand. Blind
settings may cause severe damage to the batteries and charge controller. Default values given
are for lead acid batteries.
ENTERING SETUP MODE:
Setup Mode, connect the settings key to the 9-PIN D-Connector. Press and hold the ENTER button on the key
and switch on the MPPT ON-OFF switch on the device till the charger enters the SETUP MODE on display. All
the indicators and fan start to function. Press the ENTER button to scroll through the setup menu as shown
below. Use the PLUS and MINUS buttons to increase or decrease the default values.
MENU
1.CAL-AMP
(AMPS
Calibration
CALIBRATION)
2.CAL-VOL
(VOLT
Calibration
CALIBRATION)
3.BVH-CUT
(BATTERY
CHARGING HIGH
CUT OFF VOLT)
4.MAX-AMP
(CHARGING AMPS)
5.GRD-SOL
(GRID TO SOLAR
CHANGE OVER)
6.SOL-GRD
(SOLAR TO GRID
CHANGE OVER)
7.BLK-LED
(LOW BATTERY
WARNING)
Note: Values will be displayed as multiples of 10 (e.g. 14.5V will be displayed as 145)
SETUPMODE
Switch OFF the device and connect to the desired battery bank. To enter
TYPE
Increase or decrease this value to match the ampere
shown on the display to the reading on your True
RMS DC clamp meter. (FLUKE brand is
recommended)
Measure the terminal voltage of the battery bank
using a DC volt meter and equalise the reading
shown in the display of the charger to your volt meter
reading
Set the battery charging
Settings
high voltage cutoff voltage
Set the maximum charging current cutoff (Max
charging current value is recommended as 20% of
Settings
the Ah of a single 12V C10 Battery connected in
series. e.g. for a 150 Ah C10 Lead Acid battery, 30A
is the recommended charging current)
Set the battery voltage you prefer to shift
Settings
automatically from grid power to inverter (solar
power)
Set the battery voltage you prefer to shift
Settings
automatically from inverter to grid power
Set the low battery level of warning indication LED to
Settings
blink
DESCRIPTION
11
RANGE
MIN
DEFAULT
MAX
50
115
220
-
-
-
13V
14.5V
16V
3A
30A
30A
12V
14.0 V
16V
9V
11.0V
16V
LB
11.7V
16V