Ashly neWR-5 Gebruikershandleiding
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Ashly neWR-5. Ashly neWR-5 6 pagina's. Programmable ethernet based remote control unit
Ook voor Ashly neWR-5: Bedieningshandleiding (4 pagina's), Bedieningshandleiding (4 pagina's)
Ashly neWR-5 Remote Control User Reference
Introduction
The neWR-5 is a programmable ethernet based remote control
unit for all Ashly NE (network enabled) products, including NE pro-
cessors, NE power amplifiers, Pema amplifiers, and nX networked
amplifiers. This remote brings control features such as preset recall/
scroll, mute, zone source selection, individual channel and matrix
point level control, and logic output control throughout a building
wherever there is a network connection. All programming is done
across the network using Ashly Protea
This device complies with part 15 of the FCC Rules for class A operation, and is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may
cause undesired operation.
Features
The neWR-5 is designed to mount into a standard earth ground-
ed North America electrical wall box. A decora cover plate (not
included) can be purchased at hardware stores to cover the neWR-5
electrical box and satisfy the aesthetic needs of the installation.
Connecting and powering the neWR-5 requires Cat-5 ethernet
cable and a IEEE 802.3af Power over Ethernet (PoE) switch, hub, or
inline PoE injector. If PoE is unavailable, a 15-48VDC power sup-
ply capable of at least 2 watts per neWR-5 can be hard wired to a eu-
roblock connector on the back of the remote. The RJ-45 connector
has a green LED to indicate an Ethernet connection has been made,
and a yellow LED to indicate data is being transferred. There is a
hard-wired Lock-Out feature on the neWR-5, where the closing of a
switch wired to the lockout euroblock renders all buttons inactive.
The neWR-5 has six programmable function buttons which can
light up green, red, or amber to display status. To the right of the func-
tion buttons is a pocket in the mylar overlay for a paper function label to
be inserted. The two other buttons are used to adjust function parame-
ters such as gain or preset number, and are indicated by the LED display.
Hardware Installation
The neWR-5 Ethernet control connection is made using an RJ-45 terminated eight conductor
cable connected directly to a computer, or indirectly over a standard 10/100M Ethernet network.
Maximum cable distance for Ethernet is 100 meters from the nearest hub or switch for copper
585-872-0010
software.
ne
FCC Compliance
Ashly Audio Inc
847 Holt Rd
toll free 800-828-6308
Webster NY 14580
fax 585-872-0739
www.ashly.com