BlueSky Designs Mount'n Mover DP-T5 Handleiding voor bevestiging - Pagina 4
Blader online of download pdf Handleiding voor bevestiging voor {categorie_naam} BlueSky Designs Mount'n Mover DP-T5. BlueSky Designs Mount'n Mover DP-T5 4 pagina's. Tobii i-13
Set up for I-13 and I-16 with a Universal Rotator (DP-UR)
A
Set up for IR access
Rotator used with Extension plate
for access to Infrared window.
4
Attach DP-EXT to DP-UR
Knob can
be on left
or right
sides
Attach the Extension Plate (DP-EXT) to
the Rotator (DP-UR) with four screws
labeled "Attaching QRP to Rotator"
(8-32 x 3/16"). Note the Rotator knob
can be on left or right side.
1
Parts needed
DP-T5
DP-UR
DP-EXT
The DP-T5 includes:
1. Spacer
2. QCR
and four 8-32 x 2" screws
5
Attach QRP to DP-EXT
DP-EXT
QRP
Attach the QRP to the threaded
inserts on the DP-EXT with four
screws (8-32 x 1/4") labeled
"QRP to Device Plate".
2
3
Turn Rotator
a
Two screws
through
countersunk
Loosen
knob
holes into QCR
b
Locate attachment holes
Loosen the knob and spin
Use two of the 8-32 x 2" screws through
the Rotator to reveal the
two of the holes in the DP-UR, through
attachment holes.
the DP-T5 spacer, and into the threaded
holes in the QCR. The other 2" screws
attach the spacer to the QCR.
No IR access
B
Attach the QRP to the threaded
inserts on the DP-UR with four
screws (8-32 x 3/16") labeled
"QRP to Rotator".
Attach DP-UR to DP-T5
Two screws
through DP-UR
DP-UR
countersunk
holes
Spacer
QCR
1
Parts needed
DP-T5
DP-UR
(See above steps #2 + #3)
2
Turn Rotator
3
Attach DP-UR to DP-T5
4
Attach DP-UR to QRP
QRP
page 4 of 4