ELECTRICAL CONNECTION OF HAND DRYER:
Electrical supply entry holes are located in the rear of the cabinet at lower
right corner of the dryer mounting base and at the right side of the cabinet.
Supply cable with supplementary insulation into one of these locations in
the unit cabinet. Cabinet should be fitted with a conduit connection. Plastic
grommet supplied to use as necessary.
1. Connect dryer to nearest distribution panel. Use wire as required
by local electrical code, 3.31mm² dia. (No. 12) wire or larger.
2. Wiring Instructions:
a.
This appliance is intended for connection to fixed wiring.
b. A fused means for disconnection in all poles must be provided
in the fixed wiring in accordance with the wiring rules.
c.
Check that the electrical rating shown on the dryer (rating
label) is compatible with the electrical supply.
d. WARNING: THIS PRODUCT MUST BE GROUNDED
(EARTHED).
e.
Installation and wiring must conform to current IEE
Regulations (UK), local or appropriate regulation (other
countries).
f.
For 115-Volt dryers: Connect ground wire to ground terminal
marked
, the black or hot wire to terminal marked L1, and neutral or
white wire to terminal marked N
For 208–240 Volt dryers: Connect ground/earth supply the terminal marked
marked L (L1) and N (L2).
3. Secure electrical wire in strain relief clamp provided on mounting base.
CHECK DRYER OPERATION:
1. Turn electrical power supply on.
2. Position hands under air outlet, within 100mm (4") of air outlet opening.
3. Dryer should turn on. Warm air should blow from air outlet.
4. Remove hands from under air outlet and dryer should stop (within 2 seconds).
GENERAL OPERATING CONDITIONS:
The following minimum machine operating environmental parameters must be met in order to allow proper dryer operation:
1. The equipment will operate correctly in its intended ambient operating temperature range, at a minimum, between
+5°C (41°F) and +40°C (104°F).
2. The equipment will operate correctly within a relative humidity environment at 50%RH, +40°C (104°F). Higher RH may
be allowed at lower temperatures. Measures shall be taken by the Purchaser to avoid the harmful effects of occasional
condensation.
3. The equipment will operate correctly up to 2000m (6,560ft) above mean sea level.
4. The equipment will operate in a normal office type Pollution Degree 2 environment.
5. The mains supplies in this equipment are designed to work at +/-10% voltage fluctuation of the marked rating.
MAINTENANCE:
WARNING: Motor laminations are live. Turn electrical power supply
off before doing any maintenance or service to dryer. Electrical power
supply must be off unless dryer cover is secured.
1. Turn electrical power supply on.
2. Position hands under air outlet, within 100mm (4'') of air outlet
Form No. 38030-369 Issued 7/29/21
Figure 4
To remove dryer cover, remove two screws
from the bottom of the Dryer and two from
the sides, as shown in Figure 4.
© 2021 by Bobrick Washroom Equipment, Inc.
and the 208-240 Volt wires to terminals