DoorHan DHRE-2 Instrukcja instalacji i obsługi - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Odbiornik DoorHan DHRE-2. DoorHan DHRE-2 3 stron. External radio
Również dla DoorHan DHRE-2: Instrukcja instalacji (3 strony), Instrukcja instalacji i obsługi (3 strony), Instrukcja instalacji i obsługi (2 strony)
EC DECLARATION OF CONFORMITY
We: DoorHan Europe s.r.o.
Bozeny Nemcove 1689, 43201 Kadan, Ceska Respublika Herewith declare under sole
responsibility that:
• Declares that: The device model Reciever outside 433MHz 2 chan-
nels (DHRE-2)
• Сomplies with the essential safety requirements of the following
directives:
73/23/EEC and subsequent amendment 93/68/EEC
89/336/EEC and subsequent amendment 92/31/EEC
and 93/68/EEC
Additional note:
These products have undergone tests in a typical uniform configuration
(all products manufactured by DoorHan Europe s.r.o.)
01/03/2010
Date
1. FUNCTION
External receiver DHRE-2 is intended for receiving a radio signal of the remote control
panel at 433MHz frequency, decoding and control signal (NO) generation for controlling
electric operators.
2. OVERALL DIMENSIONS
А = 63 мм
В = 90 мм
С = 25 мм
3. TECHNICAL SPECIFICATIONS
Operating frequency, MHz
Power supply voltage (DC), V
Useful current, mA
Max. number of panels per one channel, pc
Number of channels, pc
Operating temperature, °С
Actual versions
4. CONNECTION
1. You should connect this device to a power supply 12/24V DC using terminals
+24V and GND.
2. You should connect electric operator control contacts to radio receiver output ter-
minals CH1 or CH2.
5. PROGRAMMING
1. Receiver memory clearance. After you have switched on power supply, you should
press and hold a panel programming button «CODE1» or «CODE2», depending on the
channel you wish to clear. A short beep will sound. The indicator «LED1» will go on for
10 seconds, then it will go out, and a long beep will sound acknowledging the erasure of
memory programmed codes.
2. Programming of Doorhan panels in the receiver. For panel programming you should
press and release a panel programming button «CODE1» or «CODE2», depending on the
channel you wish to program. The red indicator A will go on and a short beep will sound.
You should press the selected button (which you later on wish to use for unit control) on
the panel twice within 10 seconds when the red indicator «LED1» is on. The indicator A
will go out and a short beep will sound, meaning the successful programming of the panel
code in the receiver memory.
Note:
• 3 long beeps will sound when there is the receiver memory overflow.
3. Setting of several panels. For setting several panels you should repeat item 2 for
each new panel.
6. REMOTE PANEL PROGRAMMING
Within the interval of 1 - 4 seconds you should act as follows:
1. You should press and hold button 2 (see Figure) of the programmed panel.
2. You should press and hold button 1, not releasing the pressed button 2.
3. You should release all pressed buttons.
4. You should press the programmed panel button; the receiver will enter the panel
programming mode. A short beep will sound.
Note:
• After you have entered the programming mode the panel programming is possible
within 8 seconds, after these 8 seconds expire the receiver will quit the programming
mode.
5. You should press the button, which you later on will use for receiver channel control,
on a new panel twice. A short beep will sound, meaning the programming of the panel
code in the receiver memory.
Note:
• 3 long beeps will sound when there is the receiver memory overflow.
• It is necessary to perform panel programming within the receiver range.
• A number of the button can be defined by points on a panel body.
1
4
3
2
DoorHan thanks you for purchasing our products. We hope that you will remain satisfied
by quality of this product. If you have any questions on purchasing, distribution and
servicing, please contact our regional representatives' offices or company headquarters at
the address:
Czech Republic, Kadan, 43201, Kralovsky VRCH 2018.
Phone: +420-474-319-111, сell: +420-607-508-343, e-mail: [email protected],
OPERATION MANUAL FOR
EXTERNAL RECEIVER DHRE-2
Mikhail Kiselev
Open
Ch1
Ch2 +24GND
3
2
1
4
web: www.doorhan.cz
INSTALLATION AND
Managing Director
signature
С
433
12/24
50
110
2
-40..+55
soft - v 1.0
pcb - v 1.0
12VDC
- +
1
2
1
2