Faulty scanning
*1: Replace the print head only after the print head deep cleaning is performed 2 times, and when the problem persists.
A part of a line is missing on printouts.
Color hue is incorrect.
Printing is incorrect.
No ejection of black ink.
Graphic or text is enlarged on printouts. When enlarged in the carriage movement direction:
No scanning.
Streaks or smears on the scanned image. - Clean the platen glass.
<2. LIST OF ERROR DISPLAY / INDICATION>
- Perform nozzle check pattern printing, and confirm that
ink is properly ejected from all the nozzles.
- Replace the
- ink tank, or
*1
- print head
.
- Confirm that the ink tanks are installed properly.
- Perform print head maintenance.
- Replace the
- ink tank, or
*1
- print head
- Perform print head alignment.
Replace the logic board.
- Confirm that the ink tanks are installed properly.
- Perform print head maintenance.
- Replace the
- ink tank, or
*1
- print head
.
- Remove foreign material from the purge unit caps, if any.
- Replace the purge unit.
- Clean grease or oil off the timing slit strip film.
- Replace the
- timing slit strip film,
- carriage unit,
- logic board, or
- scanning unit (when copying)
When enlarged in the paper feed direction:
- Clean grease or oil off the timing slit disk film or the
timing slit disk eject film.
- Replace the
- timing slit disk film,
- timing slit disk eject film,
- timing sensor unit,
- LF roller,
- platen unit,
- logic board, or
- scanning unit (when copying)
- Confirm the connection between the scanning unit and the
logic board.
- Replace the
- scanning unit, or
- logic board.
- Confirm that the MP drivers are installed properly.
- Confirm that the USB cable is connected properly.
- Confirm the connection between the scanning unit and the
logic board.
- Replace the
- scanning unit,
- logic board, or
- document pressure plate sheet.