Standard Configurations and Options
The CS-5100 has made since 1994. The latest version of the control (main) circuit board operates on
24VDC. This is a common industrial standard voltage source. Since our older cards operated on either
115 or 230 VAC, our standard configuration of the main board includes a small, 0.8W power supply, as
shown below. The supply accepts any AC power source between 90 and 240VAC. The supply requires
only L1 and L2. Connect incoming ground to the subpanel or enclosure.
The CS-5100, CS-5140 or CS-5103 may be ordered without the supply (-LPS) when a 24VDC source
of sufficient amperage is available.
Any of the CS-5100 series controls may be ordered with an M12 connector termination.
The layout of the CS-5100's main processor board with power supply is shown at right.