SLAVE PANEL COMMUNICATION LEDS

 Slave EX100 Communication LEDs
The slave EX100 RS485 communications are indicated by RX485 - LED1 and TX485 -
LED2. The green TX RS485 LED will only toggle when the address of the Slave H1000
is sent from the Master H1000 control panel. When the Slave H1000 receives this poll
it will send the response to the Master H1000 panel. See previous section which
describes the "Master H1000 EX100 Communications"
RX485 LED
 Slave H1000 RD8, RD7, RD6 LEDs
RLED8
RLED7
An additional H1000 Slave setup verification is implemented in this firmware. Three
LEDs are used to indicate what address the H1000 Slave panel is set to. These LEDs
near the reader ports RD8, RD7 and RD6 are labeled as RLED8, RLED7 and RLED6
respectively. Each time the Master control panel communicates to the H1000 Slave one
of these LEDs will toggle. If the Slaves have been correctly configured, the correct LED
that will toggle is indicated below:
Slave 1 = RLED8
Slave 2 = RLED7
Slave 3 = RLED6
TX485 LED
RLED6
H1000 Elevator Control
Installation Guide
Page 13 of 20
October 2015 • Rev. 1.7