DOTECH FX3DH Series Podręcznik użytkownika - Strona 5
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Kontroler DOTECH FX3DH Series. DOTECH FX3DH Series 9 stron. Digital temp. & humidity controller
Również dla DOTECH FX3DH Series: Podręcznik (4 strony)
Setting 1 Group
(PRG Button Push for 3 Sec.)
No
Menu
4 0016
Select Control Type
4 0017
Control Deviation Value
4 0018
Select Deviation Value
4 0020
ON Delay Time (※1)
E V 1
4 0021
Minimum OFF Time (※2)
Output
#1
4 0022
Minimum ON Time (※3)
4 0023
Output at Sensor Error (※4)
4 0024
Alarm Deviation Value
4 0025
Alarm Option
4 0026
High limit by user setup
4 0027
Low limit by user setup
4 0028
Manual Output Mode Output (※5)
4 0029
Manual Output Value Output (※6)
4 0031
Select Control Type
4 0032
Control Deviation Value
4 0033
Select Deviation Value
4 0035
ON Delay Time (※1)
E V 2
4 0036
Minimum OFF Time (※2)
Output
#2
4 0037
Minimum ON Time (※3)
4 0038
Output at Sensor Error (※4)
4 0039
Alarm Deviation Value
4 0040
Alarm Option
4 0041
High limit by user setup
4 0042
Low limit by user setup
4 0043
Manual Output Mode Output (※5)
4 0044
Manual Output Value Output (※6)
※
1) ON delay time : It outputs after setting delay time in spite of output condition. During ON delay time, output lamp is turned on with output after flickering in fast cycle
※
2) Min OFF Time : It lets output not occur within min. OFF time after it is turned off. During min. OFF time, output lamp is turned on with output after it flickers every 1 second intervals
※
3) Min ON Time : It is for avoiding frequent ON/OFF of control output and maintains ON condition in spite of OFF condition during Min ON Time after being turned on.
(In case of sensor error, OFF at once)
※
4) Output at Sensor Error : In case of sensor error such as open wire/short, it sets ON/OFF status of the related output.
※
5) Manual Output Mode : OFF : Output by PV / ON : Output by
※
6) Manual Output Value Setup : It outputs continuously regardless of PV. if manual output value is ON when manual output mode is ON. (-R4 model)
Code
Unit
OFF (0) : Display
C (1) : Cooling mode
H (2) : Heating mode
AL I (3) : Deviation high limit alarm
AL2 (4) : Deviation low limit alarm
TY1
AL3 (5) : Deviation high, low limit alarm
AL4 (6) : Deviation high, low limit reverse alarm
AL5 (7) : Absolute value high limit alarm
AL6 (8) : Absolute value low limit alarm
SBA (9) : Sensor open wire alarm
K
DF 1
P (0) : Deviation
TP 1
DT 1
Sec
Sec
FT 1
Sec
NT 1
SF 1
K
H Y 1
ALA (0): General alarm,
A P 1
ALC (2): Standby alarm,
%, °C
U H 1
%, °C
U L 1
OFF (0) : Output by PV
M D 1
(Present Value)
OFF (0) : Always output OFF
M V 1
OFF (0) : Display
C (1) : Cooling mode
H (2) : Heating mode
AL I (3) : Deviation high limit alarm
AL2 (4) : Deviation low limit alarm
TY2
AL3 (5) : Deviation high, low limit alarm
AL4 (6) : Deviation high, low limit reverse alarm
AL5 (7) : Absolute value high limit alarm
AL6 (8) : Absolute value low limit alarm
SBA (9) : Sensor open wire alarm
K
DF 2
P (0) : Deviation
TP 2
Sec
DT 2
Sec
FT 2
Sec
NT 2
SF 2
K
H Y 2
ALA (0): General alarm,
A P 2
ALC (2): Standby alarm,
%, °C
U H 2
%, °C
U L 2
OFF (0) : Output by PV
M D 2
(Present Value)
OFF (0) : Always output OFF
M V 2
MVI,MV2
(-R4 model)
- 5 -
Step
Min
0.1
0.1
PN (1): ± Deviation
1
0
1
0
1
0
OFF (0)
0N (1)
0.1
0.0
ALB (1): Maintain alarm,
ALD (3): Maintain & standby alarm
1
U L 1
1
-50
U H 1
ON (1) : Output by MV2
(-R4 model)
ON (1) : Always output ON
0.1
0.1
PN (1): ± Deviation
1
0
1
0
1
0
OFF (0)
0N (1)
0.1
0.0
ALB (1): Maintain alarm,
ALD (3): Maintain & standby alarm
1
U L2
1
-50
U H 2
ON (1) : Output by MV2
(-R4 model)
ON (1) : Always output ON
Max
Default
Custom Setup
C (1)
99.9
2.0
P (0)
999
1
999
5
999
5
OFF (0)
99.9
1 .0
ALA (0)
1 05
1 00
0
OFF (0)
OFF (0)
H (2)
99.9
2.0
P (0)
999
1
999
5
999
5
OFF (0)
99.9
1 .0
ALA (0)
1 05
1 00
0
OFF (0)
OFF (0)
R20160613