Dahl VARIODOCK Podręcznik konserwacji - Strona 6
Przeglądaj online lub pobierz pdf Podręcznik konserwacji dla Stacja dokująca Dahl VARIODOCK. Dahl VARIODOCK 19 stron.
Maintenance interval and documentation
Date: ___________ Km: ________________
Once a year or as required you must:
Carefully remove the top section of the docking station (remove the two bolts on each side). See instructions on page 21.
Clean the docking station.
Clean the locking cylinder and locking pin and lubricate with light oil.
Remove the locking pin if there are any signs of corrosion or damage (art. no. 503535).
Adjust the steel wire to the locking pin, art. no. 502400, if necessary.
All steel wires must be examined for signs of wear or evidence of breaks. Replace if necessary.
When the maintenance light is activated, VarioDock must undergo maintenance within 200 uses. Order service kit with art. no. 503636 (see also pages 34-35).
Test whether the manual emergency release functions properly and if the emergency release tool is in the vehicle.
Check whether the wires are loose in the terminals and whether they are intact and insulated. Replace if necessary.
Test whether the electromagnet/solenoid functions correctly.
Test whether the micro switch, art. no. 503640, functions correctly.
Test whether the warning tone (high-pitched howl) is activated and functions correctly.
Test whether the light diodes in the control panel function correctly along with the warning tone.
Check whether any nuts, bolts or screws are loose or damaged. Tighten/replace if necessary. This also applies to the lock plate and its fitting under the wheelchair.
Maintenance carried out:
Replaced parts:
Stamp
Next maintenance:
Date: ___________
10
Maintenance manual, installation and user guide UK
Maintenance interval and documentation
Date: ___________ Km: ________________
Once a year or as required you must:
Carefully remove the top section of the docking station (remove the two bolts on each side). See instructions on page 21.
Clean the docking station.
Clean the locking cylinder and locking pin and lubricate with light oil.
Remove the locking pin if there are any signs of corrosion or damage (art. no. 503535).
Adjust the steel wire to the locking pin, art. no. 502400, if necessary.
All steel wires must be examined for signs of wear or evidence of breaks. Replace if necessary.
When the maintenance light is activated, VarioDock must undergo maintenance within 200 uses. Order service kit with art. no. 503636 (see also pages 34-35).
Test whether the manual emergency release functions properly and if the emergency release tool is in the vehicle.
Check whether the wires are loose in the terminals and whether they are intact and insulated. Replace if necessary.
Test whether the electromagnet/solenoid functions correctly.
Test whether the micro switch, art. no. 503640, functions correctly.
Test whether the warning tone (high-pitched howl) is activated and functions correctly.
Test whether the light diodes in the control panel function correctly along with the warning tone.
Check whether any nuts, bolts or screws are loose or damaged. Tighten/replace if necessary. This also applies to the lock plate and its fitting under the wheelchair.
Maintenance carried out:
Replaced parts:
Stamp
Next maintenance:
Date: ___________
11
Dahl VarioDock™