Baumer GNAMG Series Podręcznik - Strona 29

Przeglądaj online lub pobierz pdf Podręcznik dla Akcesoria Baumer GNAMG Series. Baumer GNAMG Series 41 stron. Inclination sensor with canopen interface

Baumer GNAMG Series Podręcznik
Object 6111
Operating parameter Y-axis (Slope long operating parameter) (not with 360° sensor)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Object 6112
Preset value Y-axis (Slope long preset value) (not with 360° Sensor)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Objekt 6113
Offset Y-axis (Slope long offset) (not with 360° sensor)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Objekt 6114
Differential Offset Y-axis (Differential slope long offset) (not with 360° sensor)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Manual_GNAMG_CANopen_EN.doc
21.11.12
0
Unsigned 8
ReadWrite
0h
Yes
Inversion:
Inversion enable means reverse polarity of the Y-axis.
Scaling:
Scaling enable means calculating the slope of the Y-axis as follows:
Slope Y –axis = physically measured slope + differential offset Y- axis + offset
Y-axis
When scaling is disabled:
Slope Y –axis = physically measured angle
Bit 0 = 1 inversion on
0 inversion off
Bit 1 = 1 scaling on
0 scaling off
0
Integer 32
ReadWrite
0h
Yes
Sets the actual slope value Y-axis to the desired value
Value range depending on parameters in object 6000h
0
Integer 32
ReadOnly
0h
Yes
Calculated offset when writing on object 6112h
Offset Y-axis = Preset value Y-axis at t
– d
t
value Y- axis at
ifferential offset Y- axis
acc
Value range depending on parameters in object 6000h
0
Integer 32
ReadWrite
0h
Yes
Supplementary offset, independent from objects 6112h and 6113h
The entered value is directly added to the current slope of the Y- axis
Value range depending on parameters in object 6000h
physically measured slope
acc
29/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany