OPERATIONAL TEST AND FINAL ADJUSTMENTS

HYDRAULIC UNIT

WARNING
Keep 8' clear of the blade when it is being
raised, lowered, or angled. Do not stand
between vehicle and blade or directly in front
of the blade. If the blade hits or drops on you,
you could be seriously injured.
The MVP PLUS™ snowplow hydraulic unit comes
from the factory pre-assembled, partially filled, and
fully tested.
1. Attach the snowplow to the vehicle according to
the instructions on the back of the blade.
2. Remove and discard the factory‑installed pipe
plug from the top of the reservoir and install the
breather.
Fill Plug
AeroShell
is a registered trademark (
®
Lit. No. 43174, Rev. 04
Breather
Drain
Cap
) of Shell Oil Company.
®
To prevent accidental movement of the blade,
always turn the control OFF whenever the
snowplow is not in use. The power indicator
light will turn OFF.
3. Turn the control ON and completely extend and
retract the driver‑side wing several times. Repeat
for the passenger‑side wing. With both wings fully
retracted, raise and lower the snowplow several
times. Activate the control FLOAT function and
manually collapse the lift ram all the way. Turn the
control OFF.
Do not mix different types of hydraulic fluid.
Some fluids are not compatible and may
cause performance problems and product
damage.
4. Remove the fill plug and check the fluid level.
With the snowplow wings and lift ram fully
retracted, the fluid level should reach the fill hole.
If additional fluid is needed, fill the reservoir with
WESTERN
High Performance Hydraulic Fluid
®
rated to –40°F (–40°C), or other fluid conforming
to Military Specification MIL-H-5606 A, such as
Mobil Aero HFA or Shell AeroShell
NOTE: Loosen fill plug slowly to relieve any
pressure in the reservoir.
NOTE: Add fluid only when all rams are retracted.
5. Replace and tighten the fill plug.

FLUID CAPACITY

• FloStat
Unit Reservoir
®
• FloStat System Total
10
WARNING
CAUTION
Fluid 4.
®
1-3/4 quarts
2-3/8 to 2-3/4 quarts
July 15, 2020