Baumer TA200 Instrukcja obsługi - Strona 18
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przyrządy pomiarowe Baumer TA200. Baumer TA200 28 stron. Electronic tachometer
TA200
Connection examples
18
2 System description
2.1 Description
LED symbol display
Display of time unit 1/s
Display of time unit 1/min
Display of time unit 1/h
Control panel
Adjusting key for decade selection
Adjusting key for decade values
Changeover key for function display
Changeover key for programming/control level
2.2 Block diagram
Voltage
supply
-
2
3
+
Signal F1
8
3 Connection
This chapter first describes terminal assignment, followed by some
connection examples. Chapters 3.1 to 3.3 provide concrete remarks
and specifications regarding the individual terminals. The electrical in-
puts and outputs are configured on two plug-in screw terminals. The
two 9-pole screw-type terminal is coded without pole loss.
9
8
7
6
5
Signal F1
Sensor
supply
max. 250 V
terminal - terminal /
www.baumer.com
Measuring value F1
4
3
2
1
- terminal
Sensor
supply
-
4
5
+