Advance Welding AW315 Instrukcja obsługi - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria spawalnicze Advance Welding AW315. Advance Welding AW315 15 stron.
AW315
AW315 - Operator Manual
Error 6. Low welding current.
The unit has detected a low welding current as follows:
1.5% low, fail in 3 seconds.
90% low, fail in 1 second.
• Make sure that the correct fittings are being welded.
• If multiple welding fittings, make sure the combined diameters do not exceed
200mm.
• Make sure the supply is within limits: 110 volts with a capacity of 3500 watts.
• Make sure any extension leads being used are the correct length and rating.
Error 7. High welding current.
The unit has detected a high welding current as follows:
1.5% high, fail in 3 seconds.
6.25% high, fail in 2 seconds.
12.5% high, fail in 1.5 seconds.
25% high, fail in 1 second.
50% high, fail in 0.3 seconds.
• Restart the weld after the fitting has returned to ambient temperature.
• If the fault persists, return the unit to an approved service agent.
To reset the unit after an error, press and hold-in the Start/Stop button for five
seconds.
© 2019. Advance Welding
10