installation summary
Below is a summary of the key steps for the successful installation of a Connected TE controller and Gateway. Details of the
installation are presented in subsequent sections.
1) Physical Installation
a) Gateway installation & location
i) Check for good cell signal
ii) 120VAC or 240VAC power outlet (depending on gateway model) located near gateway, within 5 feet or 1.5 meter
III) Mount box to wall
iv) Install 2 antennas
v) Plug RS485 Interface Board into Port 2 on the gateway and secure using the two screws
b) Route supplied network communications cable from Gateway to splitter for Connected TE 1
i) Route the cable efficiently to Controller 1 / Node 1
c) Setup Connected TE Controllers
i) Connect splitters to each Controller
ii) Connect Controller 1 / Node 1 splitter to the gateway cable
iii) Daisy-chain remaining Controllers and splitters with interface cables (see page 5)
iv) Install terminator in open port of last splitter
v) Install and route J1 and J2 cables from the Dispenser and to the Machine Interface respectively
2) Configure Connected TE
a) Power Up TE via dispenser
b) Enter Language
c) Enter Date & Time
Note: If using multiple Connected TE controllers, each must have the same Date & Time
d) Upload setup file from the USB created if using the Formula Editor.
e) Go to Installer Menu – Initial System Setup
Note: These steps must be followed for a Connected TE to operate properly and produce accurate real-time reports
i) Node Address – Add the node address (1, 2, 3, or 4) which must be unique for each Connected TE controller
ii) Account Name – Confirm or create
iii) Company Name – Confirm or create
iv) Machine Name – Confirm or create
v) Date - Confirm
vi) Time - Confirm
vii) Timezone - Confirm or select.
viii) Daylight Savings Time – Enable if in a Daylight Savings time zone
3) Prime and Calibrate each Product
Note: All products must be primed and calibrated for the system to operate