Dover Hydro Connected Total Eclipse Skrócona instrukcja obsługi - Strona 3
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Kontroler Dover Hydro Connected Total Eclipse. Dover Hydro Connected Total Eclipse 17 stron.
installation details
Machine Interface Installation
1) Route MI signal wires through knock-out on washer within the wiring
area (approximately 3/4 inch or 20mm). Use lock nut on MI nipple to
secure MI to washer.
Machine Interface (MI)
Front
J2 Cable Connection
2) Connect cable marked J2 into Machine Interface. Bundle excess J2
cable outside washer and connect other end to the connector labeled
J2 on the rear of the Controller.
3) Connect cable marked J1 from the dispenser module to the connector
labeled J1 on the Controller.
4) For additional cable strain relief, secure J1 and J2 cables to controller
tie-down posts with cable ties (aka tie wraps, zip ties).
Connected Total Eclipse Controller (rear)
J1 Cable
J2 Cable
Signal Wire Installation
The Machine Interface will work with any signal voltage between 24 –
240VAC or 22 – 24VDC. With DC signals, polarity must be observed,
where common connects to negative. The signals must be positive
voltages.
Supply Trigger Wiring:
1) Identify the washer supply signals. Check with technical service or with
the washer manufacturer if you are not sure of the connections.
2) Identify the Mode of Operation to be used. Use appropriate terminal
connectors to connect the signal wires to the Machine Interface wires,
based upon the table on the next page.
Rear
Signal Wires
Lock Nut
Cable Ties
WARNING! The Connected Total
Eclipse controller is intended to be
installed by a qualified technician
only, in accordance with all applicable
electrical and plumbing codes.
DISCONNECT POWER to the
laundry machine and dispenser
during installation and/or any time the
dispenser cabinet is opened.
WARNING! Keep the Machine
Interface and the communication
cables away from high voltage wires
and relays. NEVER run the J1 and J2
cables parallel with high voltage lines.
NOTE: This manual describes only the
installation and programming of the Connected
Total Eclipse Controller, which is a portion of
the larger Chemical Management System.
Please refer to the reference manual included
with your dispenser or upgrade kit for
additional instructions.
Electrical wiring connections for supply triggers
are to be done inside the supply junction box.
(See section 3.03 "Supply Trigger Wiring" on
page 16 for detailed connection information.)
NOTE: The maximum distance for the J1 cable
from the product dispenser to the controller is
75 feet or 22 meters.
•
"J" cables are available in 15 and 30
foot lengths (4.5m and 9m). A coupler is
available to join cables together for longer
distances, but thy must always be under 75
feet or 22 meters.
•
"J" cable runs longer than 75 feet or 22
meters require the use of break out boxes
and hard wiring. Contact Hydro Systems for
details.
WARNING! Always verify all voltage
sources with a voltage meter.
DISCONNECT POWER to the
laundry machine and dispenser
during installation and/or any time the
dispenser cabinet is opened.
3