Please take reference of the way recommended by manual to place the product. All devices
must be firm during installation. Please arrange the stacked number of devices
actual needs. Don't install batteries on sloping and unstable ground.
6.4.2 Ground wire connection
Please unscrew the screw at the ground hole on front panel, install the ground terminal on
the screw and tighten it with a screwdriver. The other end of ground wire is connected to the
nearby bracket, and the whole is connected to a reliable ground point.
Attention: the ground resistance <4Ω .
6.4.3 Power cable connection
Please check the continuity of the cable, distinguish the positive and negative terminals, and
label the cables before connecting power cable. Please also check whether there is short circuit
and reverse connection after the cable connection is finished. The checking method is as
follows:
Cable continuity: please adjust to the buzzer gear of multimeter and test two ends of the
cable by a probe. If the buzzer sounds, the cable is available.
Voltage diagnosis: please adjust to the DC voltage gear of multimeter and test the positive
and negative electrode of battery by a probe. If it indicates the voltage within the normal range,
the product can be used.
6.4.4 Cables connection
Please take reference of the following description of wiring method for installing battery
pack.
A single battery: please connect the positive electrode of battery with the DC positive
electrode of inverter by a red cable, and connect the negative electrode of battery with the DC
negative electrode of inverter with a black cable.
Multiple batteries: please adopt the parallel connection method between battery and battery
or battery and inverter. At first, please connect the positive terminals of the adjacent 2
batteries respectively by a red cable, and connect the negative terminals of the adjacent 2
batteries respectively by a black cable. Second, please connect the positive electrode of battery
with the DC positive electrode of inverter by a red cable, and connect the negative electrode of
battery with the DC negative electrode of inverter by a black cable.
Communication cable, please connect the CAN interface of battery with the communication
interface of inverter. The RS485 interface of battery is used for the communication connection
of two batteries.
User Manual of Home Energy Storage System (Split Type)
flexibly as
13